DECLARATION OF CONFORMITY
Application of Council Directive: 2004/108/EC -The EMC Directive
Manufacturer's Name: Teledyne Isco, Inc.
Manufacturer's Address:
4700 Superior, Lincoln, Nebraska 68504 USA
Mailing Address: P.O. Box 82531, Lincoln, NE 68501
Equipment Type/Environment: Laboratory Equipment for Light Industrial/Commercial Environments
Trade Name/Model No: Pro20 and Hot Tap Sensor
Year of Issue: 2007
Standards to which Conformity is Declared: EN 61326:1998 EMC Requirements for Electrical Equipment for
Measurement, Control, and Laboratory Use
Standard Description
Severity
Applied
Performance
Criteria
EN61000-4-2
Electrostatic Discharge
Level 2 - 4kV contact discharge
Level 3 - 8kV air discharge
C*
EN61000-4-3
Radiated RF Immunity
80 MHz to 1000MHz 80% AM at 1kHz
Level 1 – 10V/m
B**
EN61000-4-4
Electrical Fast Transient
Level 2 – 2kV on AC lines
C***
EN61000-4-5
Surge on AC Lines
2kV L-Gnd, 1KV L-L
C***
EN61000-4-6
Conducted RF on AC lines
150 kHz to 80 MHz,
3V rms, 80% modulated
B**
EN61000-4-11
AC Dips and Short Interruptions
0.5 Cycle, each polarity/100%
A
CISPR11/
EN 55011
RF Emissions
Group 1, Class A Industrial, Scientific, and
Medical Equipment
Passes
EN61000-3-2, 3-3
Harmonic, Flicker
Passes
*Unit is susceptible to ESD. In dry environments (<40% humidity), user must discharge themselves to earth before touching front
panel to prevent program lock-up.
**Unit’s flow sensor/cable is susceptible to RF. Unit must not be located near an RF source (radio/TV tower) to prevent erroneous
flow/depth measurements.
***Unit is susceptible to AC line transients and/or surges. If program lock-up occurs, unit’s wall mount power supply must be
connected to an AC power conditioner or operated on its internal batteries.
We, the undersigned, hereby declare that the design of the equipment specified above conforms to the above Directive(s) and
Standards as of July 5, 2007
William Foster
USA Representative
William Foster
Director of Engineering
Teledyne Isco, Inc.
4700 Superior Street
Lincoln, Nebraska 68504
Phone: (402) 464-0231
Fax: (402) 464-4543
60-7102-003
Rev. A
Summary of Contents for ADFM Hot Tap
Page 2: ......
Page 4: ......
Page 20: ...ADFM Flow Meter Section 1 Introduction 1 10 ...
Page 85: ...ADFM Flow Meter Section 2 Setup and Installation 2 65 Figure 2 73 Viewing data in Expert View ...
Page 86: ...ADFM Flow Meter Section 2 Setup and Installation 2 66 ...
Page 98: ...ADFM Flow Meter Section 3 Maintenance and Troubleshooting 3 12 ...
Page 114: ......
Page 116: ......