Sentinel V SC and RT Operation Manual
September
2017
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Page 273
BIT POSITIONS
BYTE
7
6
5
4
3
2
1
0
13
V Ref
14
15
VGG
16
Figure 110.
Sentinel V ADC Data
Table 46.
Sentinel V ADC Data
Binary
Byte
Field
Description
1,2
ID Code
Stores the Sentinel V – ADC data identification word 7002 (70 02h). LSB is
sent first.
3-4
V In
Reserved for TRDI use. All fields are used for advanced system diagnostics.
5-6
I In
Reserved for TRDI use. All fields are used for advanced system diagnostics.
7-8
V IO
Reserved for TRDI use. All fields are used for advanced system diagnostics.
9-10
V Core
Reserved for TRDI use. All fields are used for advanced system diagnostics.
11-12
V DD1
Reserved for TRDI use. All fields are used for advanced system diagnostics.
13-14
V Ref
Reserved for TRDI use. All fields are used for advanced system diagnostics.
15-16
VGG
Reserved for TRDI use. All fields are used for advanced system diagnostics.
All values are scaled to 0.01 volts input from the ADC.
Sentinel V Features Data
Sentinel V Features Data output is included only in systems configured with 47.xx firmware.
The Sentinel V Features Data refers to the Sentinel V features related header data associated with the
firmware configurations. This is used to store the feature keys provisioned by the Sentinel V firmware.
The ADCP always sends this data as output data (LSBs first).
This structure is added to only the first ensemble of the Sentinel V
PD0
output. If the source
PD0
is split by
profile group, the Features Data type must be part of all individual output
PD0
s. If the ADCP does not have
any installed features, this data type is still included but it only contains the first four bytes (and byte
three is zero).
BIT POSITIONS
BYTE
7
6
5
4
3
2
1
0
1
SENTINEL V – FEATURES HEADER DATA ID (0x7003)
03h