September
2017
Sentinel V SC and RT Operation Manual
Page 202
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
IP:10.20.229.40
CN 3
Specify the IP address of the remote machine where ensemble data is going to be sent.
>cn3
Enter IP Address in dot-decimal format:
192.168.0.2
Set IP to 192.168.0.2
Saving Data to NV Memory...Done
Reconfiguring Network...Done
CN 4
Displays port number of remote machine where ensemble data is going to sent.
>cn4
Port:5000
CN 5
Specify the port number of the remote machine where ensemble data is going to sent.
>cn5
Enter Port Number:
5000
Set Port to 5000
Saving Data to NV Memory...Done
Reconfiguring Network...Done
CN 6
Displays the current broadcast settings.
>cn6
Network Directed Broadcast: Disabled
With Automatic broadcast IP detection:
>cn6
Network Directed Broadcast: Enabled
Automatic Broadcast IP Detection: Enabled
Broadcast IP (Auto Detected):10.20.230.255
With Manual Broadcast IP Entry:
>cn6
Network Directed Broadcast: Enabled
Automatic Broadcast IP Detection: Disabled
Broadcast IP(Manually Set):192.168.0.255
CN 7
Enables or Disables the broadcast option, and optionally selects between an auto-detected broadcast IP or
a manually entered broadcast IP address.
Auto-Detected Broadcast Mode:
>cn7
Enable Broadcast Option (y/n):
y
Set broadcast address automatically (y/n):
y
Network Directed Broadcast: Enabled
Automatic Broadcast IP Detection: Enabled