September
2017
Sentinel V SC and RT Operation Manual
Page 152
EAR-Controlled Technology Subject to Restrictions Contained on the Cover Page.
Table 10:
High Bandwidth Water Profiling
Depth Cell
Size
1
Sentinel V20
Sentinel V50
Sentinel V 100
Vertical
Resolution
Range
2
(m)
Std. dev.
3
(cm/s)
Range
2
(m)
Std. dev.
3
(cm/s)
Range
2
(m)
Std. dev.
3
(cm/s)
0.25m
18.0
19.2
0.3m
19.3
11.1
0.5m
20.2
7.1
44.1
19.2
1.0m
22.1
3.6
50.5
7.1
94.5
10.9
2.0m
24.5
1.7
56.0
3.6
103.5
5.5
4.0m
26.9
0.8
63.1
1.7
114.6
2.7
6.0m
67.4
1.1
121.7
1.8
1. User’s choice of depth cell size is not limited to the typical values specified.
2. Range, which depends on cell size, is specified here for High bandwidth mode at 5
°
C,
typical ocean backscatter and nominal 14 VDC battery power; longer ranges are possible.
Using 18 VDC will increase the range by 5 to 10% depending on conditions.
3. User selects the bandwidth mode; High = 25% or Low = 6%. High bandwidth mode single
water ping per ensemble standard deviation.
5. Table applies to Sentinel V and Sentinel V Real-Time ADCPs.
Table 11:
Low Bandwidth Water Profiling
Depth Cell
Size
1
Sentinel V20
Sentinel V50
Sentinel V 100
Vertical
Resolution
Range
2
(m)
Std. dev.
3
(cm/s)
Range
2
(m)
Std. dev.
3
(cm/s)
Range
2
(m)
Std. dev.
3
(cm/s)
0.25m
22.6
36.5
0.30m
24.0
20.8
0.5m
24.9
13.4
57.6
36.5
1.0m
26.9
6.7
64.6
13.5
120.6
20.6
2.0m
29.4
3.2
70.6
6.7
130.4
10.3
4.0m
32.0
1.6
78.2
3.2
142.3
5.2
6.0m
82.8
2.1
151.5
3.3
1. User’s choice of depth cell size is not limited to the typical values specified.
2. Range, which depends on cell size, is specified here for Low bandwidth mode at 5
°
C,
typical ocean backscatter and nominal 14 VDC battery power; longer ranges are possible.
Using 18 VDC will increase the range by 5 to 10% depending on conditions.
3. User selects the bandwidth mode; High = 25% or Low = 6%. Low bandwidth mode single
water ping per ensemble standard deviation.
4. Table applies to Sentinel V and Sentinel V Real-Time ADCPs.