LTX Patch and Splice Panel
LTX Patch and Splice Panel
Fiber :: Install guide
2 Installation Considerations
WARNING: Verify all connections meet requirements specifi ed in local electric codes or operating company guidelines before
supplying power. Unit must be protected by a listed circuit breaker or branch-rated fuse sufficient to interrupt power levels.
WARNING: Use of fully insulated tools is required when working with any AC or DC circuits.
WARNING: Fiber cables transmit invisible infrared light. To avoid eye damage or blindness, never look directly into fi bers or
connectors.
ALERT! This product must be installed and maintained only by qualifi ed technicians.
ALERT! Install this system according to company requirements. It is recommended to install the system in a Restricted Access
Location (RAL) where access is limited through use of tool (i.e., lock and key) or other means of security and be controlled by the
authority responsible for the location.
ALERT! Prior to panel installation, ensure there is enough space in front and rear to access cabling.
ALERT! Only use components and crimping tools approved by agencies or certifying bodies recognized in your country or region,
such as Underwriter’s Laboratories (UL), TUV, etc.
ALERT! Do not stand on fi ber or fi ber cables.
CAUTION! These instructions presume you have verifi ed that the Telect equipment being installed is compatible with the rest of
the system including power, ground, circuit protection, signal characteristics, equipment from other vendors, and local codes or
ordinances.
When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to
Telect Quality at
or call 1.509.926.6000. Keep all documentation that comes with your shipment.
Please read and understand all instructions before starting installation. If you have any questions, contact Telect Technical Support at
or call 1.509.926.6000.
The panel is wrapped with a high-strength plastic. Exercise care when unpacking and setting the equipment in place.
Telect is not liable for transit damage. If the product is damaged, please report it to the carrier and contact Telect Quality.
2.1 Inspection
2.2 Unpacking
The LTX Patch and Splice Panel is 7
"
H x 17
"
W x 17"D, and weighs 12 lbs. The panel comes pre-assembled as one unit.
Upon receipt of your order, carefully unpack it and compare it with the packing list and the order placed. While items described below are a
comprehensive list that includes the LTX panel, splice trays with splice sleeves, spools, brackets, and doors, the contents of your order may
vary.