![Telect LTX Install Manual Download Page 15](http://html.mh-extra.com/html/telect/ltx/ltx_install-manual_1080059015.webp)
© Telect, Inc. All rights reserved. 148326 09.08.16
1.509.926.6000 :: telect.com
15
LTX Patch and Splice Panel
LTX Patch and Splice Panel
Fiber :: Install guide
3.1.10 Install Designation Labels
Refer to
Figure 3-10
for this procedure.
Designation labels are used to identify adapter fi ber jumper
information at the front of the panel and connector pigtail fi ber
information at the rear of the panel.
1.
Open the door to the front or rear of the LTX panel all the way so
that the clear cover on the inside of the door is visible.
2.
Slide the designation label into the cover positioning it so that
numbers can be read easily with the door open.
Designation label for the front of the LTX panel (fi ber jumper
adapter side) is marked "FRONT SIDE" on the bottom corner.
Designation label for the rear of the LTX panel (pigtail fi ber
connector side) is marked "REAR SIDE" on the bottom
corner.
NOTE: After installing both designation labels, ensure they are
installed on the correct side of the LTX panel.
Figure 3-10 - Install Designation Labels
LTX Panel
Clear Cover for
Designation Label
Door
Refer to
Figure 3-11
for this procedure.
The LTX panel mounting brackets are used to attach the LTX panel to
a 19" or 23" EIA, ETSI, or WECO rack. There are two rows of screw
holes along the inside walls of the LTX panel that can be used for
mounting brackets to the LTX panel.
1.
Align mounting bracket screw holes with the screw holes in the
sidewall of the LTX panel.
2.
Insert screws through outside holes of the bracket into the panel
sidewall.
3.
Using a Phillips screwdriver, tighten screws to secure the
bracket to the panel.
4.
Repeat Steps 1 - 3 to mount bracket on adjacent sidewall of the
LTX panel.
Figure 3-11 - Install Mounting Brackets on LTX Panel
3.1.11 Install Mounting Brackets on the LTX Panel
Mounting
Bracket
Screws
LTX Panel