Energy 4004 D
Vers. 007
GB
8
4.2.1 Exhaust connection
The
Energy 4004 D
generating set comes stan-
dard with a 2 metre long exhaust pipe and a si-
lencer which must be located in a suitable posi-
tion under the platform of the vehicle. Connect
the pipe to the exhaust manifold of the generat-
ing set as shown on (Fig. 5 ref. 1).
4.3 Wiring connections
To connect to the 230 V voltage terminal board
(Fig. 6 ref. 1), use a cable suitable cross-section,
see Table 1.
A relay or change-over switch (accessory code
05423) (Fig. 7) must be installed in the vehicle
wiring system. This isolates the generating set
when it is connected to external mains.
Connect the relay proceeding as follows:
•
Connect both wires of the 230 V line of the
generating set to the PINS 1 & 3
•
Connect the user line to the PINS 7 & 9
•
Connect the outside line to the PINS 6 & 4
•
Bridge the PINS 4 & A
•
Bridge the PINS 6 - B
4.4 Battery connection
To start up the generating set, you must connect
the positive terminal (Fig. 6 ref. 3) to the positive
pole of the vehicle battery using a sheathed ca-
ble of suitable cross-section, see Table 1.
The ground cable (negative pole) (fig. 6 ref. 2)
must have the same cross section as the positive
cable and is to be connected to the vehicle chas-
sis.
The contact must be good, remove any paint or
rust or corrosion from the surface, and protect
the connection with grease.
The starter batteries must have a capacity of at
least 80 A/h.
4.5 Electronic control panel connection
Choose a suitable location inside the vehicle and
make a rectangular hole, 30 x 32 mm. Fasten the
electronic control panel (Fig. 8) using self-tapping
screws 3 x 20 mm. Do not over tight to fasten the
plastic frame.
The electronic control panel is supplied with a 5
metre long connecting cable which must be at-
tached correctly to the generating set using the
relevant connector (Fig. 9 ref. 1).
230 V LINE CONNECTION
Sez. mm
2
Length < 6 m
Sez. mm
2
Length > 6 m
2,5
4
BATTERY CONNECTION
Sez. mm
2
Length < 6 m
Sez. mm
2
Length > 6 m
25
36
TAB. 1
7
6
5