![Telair ENERGY 4004D Use And Maintenance Manual And Instructions For Installation Download Page 14](http://html1.mh-extra.com/html/telair/energy-4004d/energy-4004d_use-and-maintenance-manual-and-instructions-for-installation_1079325014.webp)
Energy 4004 D
Vers. 007
GB
14
7.4.3 Replacing the oil filter
Perform maintenance op-
erations only with the motor off.
To clean the motor oil filter cartridge, you must
remove it.
Unscrew the sealing cap (Fig. 20 ref. 1).
Remuve filter (Fig. 20 ref. 2).
Scalding hazard due to
boiling oil. Recover the used oil and dispose
of it without polluting the environment, ac-
cording to current laws.
Clean the oil filter cartridge using compressed air
to blow from inside out.
Make sure the sealing ring (Fig. 20 ref. 3) has not
been damaged, and is firmly in place.
Make sure the sealing ring (Fig. 20 ref. 4) has not
been damaged, and is firmly in place. Change
the oil filter if necessary.
Use oil to lubricate the sealing before fitting a
new cartridge.
Reassemble and refit oil filter.
Service the oil filter every
500 working hours.
8 INSTRUCTIONS ON PUTTING OUT OF
WORK AND DISMANTLING
8.2 Dismantling
Decommissioning / dismantling of the generator
set should only be undertaken by specialist wor-
kshops.
9 FIRE - IN CASE OF
In case of fire, never open the hood of the gener-
ating set and use only approved type fire extin-
guishers.
Never use water to put
out flames in the generating unit.
Electronic control panel connector
WHITE
ORANGE
GREY
BLACK
PURPLE
RED
BLUE
WHITE
GREEN
BLUE
YELLOW
YELLOW
ORANGE
PINK
RED
GREY
BROWN
GREEN
GENERATOR
20