5   OPERATING INSTRUCTIONS 

 
The 

ENERGY

 range of generating sets consist of 

endothermic Diesel motors connected to an al-
ternator able to produce alternating and continu-
ous electric power. The generating sets are as-
sembled inside a steel casing, insulated and 
sound-proofed using special sound absorbing 
materials. 
The fuel is fed to the endothermic motor by a 
pump assembled in the generating set. 

 
5.1   Machine safety 

The generating sets come with sealed casings, 
so there is no danger of contact with any rotating 
parts, high temperatures or live cables. 
The door is secured with lock and key. Keys 
must not be left within the reach of children or 
unauthorized persons. 
 

 

The generating sets 

must be used only and exclusively with their 
doors shut. 
Remove any flammable substance from near 
the generating set, for example: petrol, paint, 
solvents, etc. 
Never fill up the fuel tank while the generator 
is running. 
Never touch the generating sets or the wiring 
connections with wet hands. 
Never replace the fuses or the thermal swi-
tches using others having a higher amperage. 
Should you have to check any electrical part, 
this must be done only with the motor turned 
off and by specialised personnel.
 

 
The generating sets were made in compliance 
with the safety standards listed in the statement 
of compliance.

 

 
 
 
 
 
 
 
 

6   USING THE GENERATING SET

 

 

6.1   Starting up  

The generating set is provided with a remote 
electronic control panel which allows you to per-
form start up / turn off operations and to check 
the running conditions. 
The elements making them up are (fig. 12): 

 

1 ON/OFF 

switch 

2 Display 
3  High temperature indicator 
4  Motor minimum oil level indicator 
5  Start fail  
6 Generator 

running 

7  Motor oil change indicator 
8  Petrol reserve indicator 
9  Display changeover switch 
10 Reset 
 
Position the start switch (Fig. 12 Ref. 1) the "

ON

” 

position. The word “WAIT” will appear on the dis-
play for 8". When these have run out, the elec-
tronic control panel will start the first automatic 
procedure for starting the generator set. If the 
motor starts at the end of this phase, then “gen-
erator running” indicator (Fig. 12 ref. 6) will flash. 
Should the motor not start, this automatic proce-
dure will be repeated, up to 4 times. If the motor 
has not started at the end of this complete cycle, 
the “startup failed” indicator (Fig. 12 ref. 5) will 
light up to say that the generating set has failed 
to start. 
If only the “startup failed” indicator (Fig. 12 ref. 5) 
stays lit, you should repeat the above procedure 
several times. 
If the generating set has not started at all even 
after many attempts, you must contact your local 
service agent. 
 

 

 
 
 

12

Summary of Contents for ENERGY 4004D

Page 1: ...Vers 004 USE AND MAINTENANCE MANUAL AND INSTRUCTIONS FOR INSTALLATION GB ENERGY 4004D V 007 February 2008 GENERATORS...

Page 2: ...tank installation 9 4 7 Fuel reserve 9 5 OPERATING INSTRUCTIONS 10 5 1 Machine safety 10 6 USING THE GENERATING SET 10 6 1 Starting up 10 6 2 Turning off the generating set 11 6 3 Forbidden use 11 6...

Page 3: ...quirements laid down by the European Directive on Machine Safety This statement shall not be valid any longer if any changes are made on the machine without our written ap proval Machine GENERATOR SET...

Page 4: ...ings Note The information contained in this publica tion was correct at the time it went to print but may be modified without advance notice 1 2 Symbols and Definitions Graphic safety symbols have bee...

Page 5: ...choring bracket 8 Identification label 2 2 Identification label Fig 2 1 Generating set model 2 Model code number 3 Serial number 4 Date of manufacture 5 Power factor 6 Frequency 7 Maximum electric pow...

Page 6: ...nor Counter weight ALTERNATOR 4004 D Type Synchronous single phase self adjusting two poles brushless Max power kW 4 Continuous power kW 3 5 Voltage Frequency V Hz 230 50 Continuous current output A V...

Page 7: ...mproper installation of the generating sets can cause irreparable damage to the equip ment and compromise the safety of the instal lation engineer and invalidate guarrantee Should the generating sets...

Page 8: ...n To start up the generating set you must connect the positive terminal Fig 6 ref 3 to the positive pole of the vehicle battery using a sheathed ca ble of suitable cross section see Table 1 The ground...

Page 9: ...e Never place the fuel tank near heat sources pro tect it from any outside infiltration of water To connect the tank to the generating set use a flexible hose suitable for green petrol having an insid...

Page 10: ...personnel The generating sets were made in compliance with the safety standards listed in the statement of compliance 6 USING THE GENERATING SET 6 1 Starting up The generating set is provided with a...

Page 11: ...e generating set has start the total running hours will be displayed Press the changing key Fig 14 ref 9 to display the partial running hours of the generating set after the last change of the motor o...

Page 12: ...peration must be performed with the generating set in a perfectly horizontal position 7 4 Maintenance operations requiring specialised personnel With certain maintenance operations it is possi ble to...

Page 13: ...Used oil must not be dis posed of in the open but handed over to companies specialising in disposal and or re cycling according to the laws current in the country where such operations are per formed...

Page 14: ...ealing ring Fig 20 ref 4 has not been damaged and is firmly in place Change the oil filter if necessary Use oil to lubricate the sealing before fitting a new cartridge Reassemble and refit oil filter...

Page 15: ...c control panel connector 17 18 19 20 21 A Capacitor Power connection terminal board Temperature switch Diode bridge Fuel pump Stop electro magnet Electric fan Motor high temperature sensor 9 10 11 12...

Page 16: ...Energy 4004 D Vers 007 GB 16 DRAWING FOR SPARE PARTS LIST ENERGY 4004 D...

Page 17: ...Vers 007 Energy 4004 D GB 17...

Page 18: ...nator Dynamoschijf Polea alternador 16 01671 N 2 Staffa ancoraggio Anchor clamp Bride de fixation Befestigungsb gel Verankeringsbeugel Estribo de anclaje 17 01720 N 1 Puleggia motore Motor pulley Poul...

Page 19: ...utter M12 UNI 5587 Moer M12 UNI 5587 Tuerca M12 UNI 5587 51 00846 N 1 Cablaggio ENERGY ENERGY harness C blage ENERGY Verkabelung ENERGY Bedrading ENERGY Cableado ENERGY 53 02867 N 1 Staffa tendicinghi...

Page 20: ...ing set to control panel C ble 5 m du G n rateur au Panneau de Contr le 5 m Kabel von Generator zu Bedienpanel 5 m kabel van generator naar bedieningspaneel Cable 5 m de generador a panel de control 7...

Page 21: ...diagram Clamp 32 35 mm 01655 Final muffler 01761 Pipe FX300 inside 30 mm 00600 Clamp 32 35 mm 01655 Intermediate muffler 01760 Clamp 32 35 mm 01655 Pipe FX300 inside 30 mm 00600 Clamp inside 32 mm 00...

Page 22: ...than 14 months 16 months if delivered outside Europe after delivery ex factory In any case the costs of lubricants and consumables shall be charged Any transport expenses shall be intended as to be c...

Page 23: ...Vers 007 Energy 4004 D GB 23 Notes...

Page 24: ...minerie 18700 Aubigny sur Nere France Tel 02 48580367 Fax 02 48583585 e mail bleys teleco club internet fr Service Technique France 06 83 31 44 05 ESPA A NAUCCA CARAVANING S A Poligono Industrial CAN...

Reviews: