Vers. 002
Energy 2510 B
GB
17
Do not use silencers not
supplied by TELAIR. Silencers that have not
been specially sized may damage the motor.
4.13 Connecting an External Network Relay
An (optional) relay or change-over switch code
05423 (Fig.28) should be fitted to the vehicle wir-
ing system. Its purpose is to insulate the generat-
ing set when the vehicle is connected to an ex-
ternal electric input network.
Connect the relay (Fig.29) according to the fol-
lowing instructions:
•
Connect the two wires of the 230 V line of the
generating set to the PINS 1 - 3.
•
Connect the user line to the PINS 7 - 9.
•
Connect the outside line to the PINS 6 – 4.
•
Jumper the PINS 4 – A.
•
Jumper the PINS 6 – B.
•
Connect all the grounding cables together
Electric connections to
the generating set should be carried out by
skilled electricians only.