7.4.4 Output voltage adjustment
Adjust the voltage when the engine is hot without
any applied load and the generating set is run-
ning.
Check the voltage of the generating set using a
voltmeter via a 230 V vehicle socket. The voltage
must be between 230 V and 245 V without any
connected user.
If different values are measured, it will be neces-
sary to set the right values by working on the en-
gine rpm adjustment screw (Fig.38 Ref.1).
Turn the screw clockwise to increase the engine
rpm and consequently, the voltage.
Turn the screw counter-clockwise to decrease
the engine rpm and consequently, the voltage.
8 ROUTINE MAINTENANCE SCHEDULE
ROUTINE MAINTENANCE SCHEDULE
To be performed after the period of time or the number
of running hours listed here, whichever the earlier
.
Every
use
First
Month
or
20 hours
Every
3 Months
or
50 hours
Every
6 Months
or
100 hrs
Every
12 Mths
or
300 hrs
Engine Oil
Level check
■
Replacement
■
(2)
■
(2)
Air Filter
Clean and replace if necessary
(1)
■
(2)
Fuel Filter and
Tank
Clean and replace if necessary
■
(2)
Spark plug
Clean and replace if necessary
■
(2)
Valve
Adjust-
ment
Check - Adjust
■
(2)
Fuel Pipe
Check for leaks or cracks
■
(2)
Muffler
Check for leaks or cracks
■
(2)
Clean
and
replace
spark
screen if necessary
■
(2)
■
(2)
Air Choke Valve Check correct operation
■
(2)
Engine rpm or
Frequency
Check - Adjust
■
(2)
Vibration
Damper
Sus-
pension Points
Check – Replace if necessary
■
(2)
NOTES: (1) Clean more frequently if you use it in a very dusty environment.
(2) These operations must be performed by specialised personnel only.