Energy 2510 B
Vers. 002
GB
18
5 OPERATING INSTRUCTIONS
The generating set is de-
livered without engine oil.
Use oil for multigrade 4-stroke petrol engines,
having SAE viscosity suitable for the operat-
ing climate and in the amount indicated (see
table and detailed indications on the user and
maintenance manual of the engine).
The ENERGY 2510 B series generators consist
of petrol internal combustion engines connected
to an alternator that can produce alternating elec-
trical current. The generating sets are assembled
inside a steel plate casing, insulated and sound-
proofed using special sound absorbing materials.
Fuel is fed to the internal combustion engine via
a pump fitted to the generating set as part of the
standard supply.
5.1 Machine safety
The generating sets come with perfectly sealed
casings, so there is no danger of contact with any
moving or high temperature parts or with live ca-
bles.
The doors open with a lock and key. The keys
must not be left within the reach of children or in-
experienced persons.
The generating sets
must only and exclusively be used with their
doors shut.
Remove any flammable substance (for exam-
ple: petrol, paints, solvents, etc.) from near
the generating sets.
Make sure that any hot parts of the generat-
ing sets are not in contact with any flammable
material.
Never fill up the fuel tank while the engine is
running.
Never touch the generating sets or the wiring
connections with wet hands.
Never replace the fuses or the cut-out
switches with others having higher amper-
age.
Should any electrical part need checking, this
must only be done with the engine turned off
and by specialised personnel.
The generating sets have been built in compli-
ance with the safety standards listed in the EEC
statement of compliance.
6 USING THE GENERATING SET
6.1 Starting up the generating set
The generating sets are provided with an elec-
tronic remote control panel (Fig. 30) which allows
you to perform starting up / turning off operations
and to check their running conditions.
The panel controls are:
1 ON/OFF switch
2 Display unit
3 High temperature indicator
4 Engine minimum oil level indicator
5 Startup failed
6 Generator running (flashing)
7 Engine oil change indicator
8 Fuel warning light
9 Display time changeover switch
10 Reset
Set the startup switch (Fig.30 Ref.1) to its “ON”
position. The message “WAIT” will be displayed
for 8 seconds. After this time, the electronic con-
trol panel will start the first automatic procedure
for starting up the generating set. If the engine
starts up at the end of this phase, the “generator
running” indicator light (Fig.30 Ref.6) will start to
flash.
Should the engine not start up, this automatic
procedure will be repeated up to 4 times.
If, at the end of a complete cycle, the engine has
not yet started up, the “startup failed” indicator
(Fig.30 Ref.5) will light up to signify that the gen-
erating set has failed to start up.
If the “startup failed” indicator (Fig.30 Ref.5) light
only stays lit, you can repeat the procedure sev-
eral times. If the generating set has not started
up after several attempts, contact the manufac-
turer’s After-sales service.