For tank anchoring to the vehicle, special
threaded inserts (Fig.18 Ref. 5 ) and (Fig.16 Ref.
7) should be used according to requirements.
4.10 Fuel reserve
Both fuel tank models are provided with a tap
with fuel warning (Fig.18 Ref.3). To electrically
connect this component, ground the wire
screwed on the tap body then connect the other
tap wire to the special three-pole connector Fas-
ton terminal via an electric lead (Fig.13 Ref. 8); to
identify the correct Faston terminal, check the
wiring diagram.
The fuel reserve available in both tanks is ap-
proximately 4 litres.
A special fuel warning light (Fig.30 Ref.8) will
light up to show that the fuel level inside the tank
has gone below the safe reserve level.
4.11 Battery charger
ENERGY 2510 B generating sets are equipped
with a battery charger which can deliver current
of approximately 10 Amp at 12 V. It can be used
to recharge the generating set start-up battery.
To obtain this function, use a 2,5 mm
2
cross-
section cable to connect the terminal identified by
CHARG (Fig.19 Ref. 1) to the positive pole (red
cable) of the generating set (Fig. 19 Ref. 2).
4.11.1 Auxiliary Battery Charger
If you wish to recharge a different battery or do
not wish to use the CHARG terminal, it is possi-
ble to use the 12 Volt alternating current output
provided on the bipolar connector shown in Fig.
13 Ref. 6. To these two Faston terminals, 4 mm²
cross-section cables should be connected to ob-
tain interfacing to an optional RCB regulator
(code 05424) as shown in Fig. 20.