Vers. 002
Energy 2510 B
GB
11
Always fit a 100 A fuse
onto the positive cable connecting the gener-
ating set to the positive pole of the battery.
4.5 Electric Load connection
To connect loads to the power generating set,
use a three-pole cable up to the applicable stan-
dards in force. The correct cross section is
shown in Table 1.
Table 1
Model
Sect. mm
2
line 230 V
Cable leng.
Lgth < 6 m
Cable leng
Lgth. > 6 m
2510B
2.5
10
16
LINE
CONNECTION 230 V
BATTERY
CONNECTION
For connection to the 230V input line, the gener-
ating set is equipped with a special terminal strip
(Fig.13 Ref.1) to which the cables must be con-
nected.
Use the special cable outlet (Fig.11 Ref.1) to
prevent water seeping into the generating set.
Although the generating set is equipped with a
special internal thermal cut-out to cut power de-
livery in the event of overload or short circuits
(Fig.13 Ref.5), it is advisable to install (in the ve-
hicle control panel) a thermomagnetic cut-out
switch, suitably set to stop power delivery to the
various users when current absorption exceeds
10.5 Amp.
If the generating set thermal cut-out switch has
been operated, press the button (Fig. 13 Ref. 5)
to restore closed circuit and power delivery con-
ditions.
Carefully check the posi-
tion of the line connection for picking up 230
Volt current. Wrong connection could dam-
age the generating set irreparably or create
dangerous short circuits.