![Tektronix TLA 700 Series Installation Manual Download Page 29](http://html1.mh-extra.com/html/tektronix/tla-700-series/tla-700-series_installation-manual_1078203029.webp)
Basic Installation
12
TLA700 Series Logic Analyzer Installation Manual
If you have any unused (empty) slots in your mainframe, install blank-slot panel
covers to meet EMC and cooling specifications. Install a blank-slot panel cover
for each empty slot as shown in Figure 8 or 9. Use only Tektronix TLA covers;
otherwise the mainframe may not meet EMC and cooling requirements.
Make sure that the EMI shielding is in contact with the adjacent panel or module
cover, and that the airflow shutter activation arms protrude through the holes in
the blank-slot panel.
Double slot
panel cover
EMI shielding strip
Figure 8: Installing panel covers on the TLA715 Portable Mainframe
EMI shielding strip
Double slot panel cover
Single slot panel cover
Figure 9: Installing panel covers on the TLA721 Benchtop Mainframe
Covering Empty Slots