Operating Basics
Reset from High Speed Measurement
This test calculates the time between the beginning of the last SOF and before the
reset and the beginning of Chirp-K for Device and HUB upstream. This must be
between 3.1 ms and 6 ms. To get the Reset from High-Speed Measurement
signal, hot-plug the unit under test (device) and measure the signaling with
single-ended probes on both lines. The application analyzes data for Reset From
High Speed Time.