Operating Basics
Configuring Inrush Current Measurements
To access the Measurements: Configure menu, go to the Measurements>
Configure.
The Configure tab allows you to set the voltage value on V
BUS
and the unit under
test. The V
BUS
can be entered manually or probed from a channel that is captured
from the test fixture. Select this option from the Source tab of Inrush
Configuration menu.
The Tier 1 is always used for testing. The unit under test can be any one of the
following types:
Hot Plug Attach
Low Powered Configure
Low Powered Resume
High Powered Configure
High Powered Unconfigure
High Powered Resume
The Hot Plug Attach is the most common unit under test. The Source tab allows
you to select the source of the signal: a live signal or the signal taken from a tsv
file. If you choose to manually enter the V
BUS
voltage, you cannot select the V
BUS
voltage source.
Configuring Droop Measurements
Select the Droop measurement and configure it. To access the Configure:
Measurements menu, go to Measurements> Configure.
The Configure tab allows you to select the Port (Port 1 through 7), Hub and
Source of the signal. The source of the signal can be live or from a .tsv file. The
hubs can either be Self-powered or Bus-powered.
36
TDSUSB2 Universal Serial Bus Measurement Package
Summary of Contents for TDSUSB2
Page 24: ...Getting Started 10 TDSUSB2 Universal Serial Bus Measurement Package...
Page 32: ...Installation 18 TDSUSB2 Universal Serial Bus Measurement Package...
Page 61: ...Operating Basics TDSUSB2 Universal Serial Bus Measurement Package 47...
Page 76: ...Taking Measurements 62 TDSUSB2 Universal Serial Bus Measurement Package...
Page 90: ...Tutorial 76 TDSUSB2 Universal Serial Bus Measurement Package...
Page 160: ...Application Examples 146 TDSUSB2 Universal Serial Bus Measurement Package...
Page 230: ...Measurement Algorithms 216 TDSUSB2 Universal Serial Bus Measurement Package...
Page 250: ...Glossary 236 TDSUSB2 Universal Serial Bus Measurement Package...