H
Calibration
—
Type
3B5
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
1.
Adjust
Trigger
Level
Centering
(R15).
Page
6-5.
+
and —
20
volt sine-wave
signal
centered
within
the
LEVEL
control range
(EXT-AC).
2.
Check
Trigger
Level
Control
Range. Page
6-6.
EXT-AC
Checked
as
part
of
step
1
EXT-DC
At
least
+
and
— 10
volts
3.
Adjust
Auto
Triggering
Centering (R35).
Page
6-6.
Stable
auto
triggering
on
a 0.5-division
display
throughout
the
rotation
of
the
LEVEL
control.
4.
Check
Low-frequency
Triggering
Operation.
Page
6-7.
Correct
triggering
with
minimum
deflection
or mini
mum
input
voltage
in
all
positions
of
the
Trigger
Function
switch.
5.
Check
Trigger
Slope
Operation
and
Coupling.
Page
6-7.
Stable
triggering
on
correct
slope
of
the
input
signal
and
indication
of
correct
trigger
coupling.
6.
Check High-Frequency
Triggering
Operation.
Page
6-8.
Correct
triggering
at
50
kilohertz
and
20
megahertz
with
minimum
deflection
or minimum input
voltage
in
all
positions
of
the Trigger
Function
switch.
7.
Adjust
Basic
Timing
(R515).
Page
6-10.
Correct
timing is 1
ms/DIV.
8.
Check
Variable
Control
Range. Page
6-11.
At
least
2.5:1.
9. Check
Sweep
Length.
Page 6-11.
Normal
sweep
10.3
to
11.3
divisions
Magnified
sweep
12
to
15
divisions
10.
Adjust Delay
Start
and
Stop
(R330
and
R333).
Page
6-12.
Alignment
of
DELAY
dial
indication
with
correspond
ing
markers
in
CRT
display.
11.
Check
Delay
Dial Incremental
Linearity
and
Accuracy
Page
6-12.
Incremental
linearity,
within
±0.4%. Accuracy,
within
±0.4%
of full
scale
at
1 ms/DIV
(with
step
10
correctly
adjusted
and
line
voltage
held
constant);
within
±3% of full scale
at
all
other
sweep
rates
12.
Check
Delayed
Sweep
Magnifier
Jitter.
Page
6-13.
3
parts
or
less
per
10,000.
13.
Adjust
One-Second
Timing
(R395).
Page
6-13.
Correct
timing
at
1
s/DIV.
14.
Adjust
One-Microsecond
Timing
(C168).
Page
6-13.
Correct timing
at
1
μ
s/DIV.
15.
Adjust
10-Microsecond
Timing
(C315). Page
6-14.
Correct
timing
at
10
μ
s/DIV.
22
16.
Adjust
0.1-Microsecond
Timing
(C502).
Page
6-15.
Correct
timing
at
0.1
μ
s/DIV.
22
17.
Adjust
High-Frequency
Compensation
(C547
and
C551).
Page
6-17.
Optimum
horizontal amplifier
response
at
50
ns/DIV
22
18.
Adjust
Registration
(R505).
Page
6-18.
No
display
shift
at
first
graticule
line
when
changing
from
0.1
μ
s/DIV
to
50
ns/DIV.
22
19.
Adjust
50-Nanosecond and
20-Nanosecond
Timing
(R508 and
C507).
Page
6-19.
Correct
timing at
50
ns/DIV
and
20
ns/DIV.
22
20.
Adjust
10-Nanosecond
Timing
(C547
and
C551).
Page
6-19.
Correct
timing
at
10
ns/DIV.
22
21.
Check
Normal
and
Page
6-20.
1s
to
10ns
5
s and
2
s
Magnified
Timing
Accuracy
Within
±3%
with
correct
readout-panel indication.
Within
±5%
with
correct
readout-panel
indication.
22
22.
Check
Operating Mode.
Page
6-23.
Instrument
operates
correctly
in the
mode
selected
by
the
EXT, MAN
and
SEEK
buttons.
22
23.
Check
Seek Mono
Pulse
Width
and
Seek
Cycling
Time.
Page
6-23.
Seek
mono
pulse
width
Seek
cyling
time
One
second
to 1.8
sec
onds.
One
to
two
seconds.
22
24.
Adjust
Cycles/Sweep (R650).
Page
6-24.
Nominal
CYCLES/SWEEP
setting.
22
25.
Check
Seek
Mode
Operation.
Page
6-24.
Correct
operation
with
seek
command
from
remote
seeking
probe,
amplifier
unit program connector,
front-panel
SEEK
button and
the
Type
3B5
PROGRAM
connector.
Does
not
seek
when
amplifier
unit
seek
button
is
pressed.
22
26.
Check
Seek
Mode
Frequency
Response.
Page
6-25.
Correct
Seek
Mode
operation
from
30
hertz
to
20
megahertz.
22
27.
Check
Multitrace
Sync
Pulse.
Page
6-25.
About
five-volt
pulses
to
amplifier
unit.
22
28.
Check
Delayed
Sweep
Magnifier
Intensifier
Levels.
Page
6-25.
Following
voltage
levels
to
indicator
oscilloscope:
DLY'D
SWP
MAG
switch
OFF
DLY'D
SWP
MAG
switch
at
X10
DLY'D
SWP
MAG
switch
at
XI
00
About
—12
volts
About
—
6
volts
during
magnified
sweep
time
About
zero
volts during
magnified
sweep time
6-3
Summary of Contents for 3B5
Page 4: ...Fig 1 1 Type 3B5 Automatic Programmable Time Base unit Type 3B5...
Page 15: ...Operating Instructions Type 3B5 TYPE 3B5 CONTROL SET UP CHART Fig 2 2 Control set up chart 2 7...
Page 48: ...CO I o Fig 3 13 Delay and Timing Circuit logic block diagram Circuit Description Type 3B5...
Page 61: ...GO i GO GO Fig 3 22 Seek Ciicuit Logic block diagram Circuit Description Type 3B5...
Page 70: ...u k KJ Fig 3 29 Circuit conditions for Manual Mode operation Circuit Description Type 3B5...
Page 71: ...w K w Fig 3 30 Circuit conditions for Seek Mode operation Circuit Description Type 3B5...
Page 72: ...w I u U Fig 3 31 Circuit condition for External Mode operation Circuit Description Type 3B5...
Page 88: ...Maintenance Type 3B5 Fig 4 9 Location of components on Logic Card 4 14...
Page 89: ...u Oi Fig 4 10 Location of components on Counter Card Maintenance Type 3B5...
Page 92: ...NOTES I...
Page 104: ...NOTES...
Page 106: ...Calibration Type 3B5 Fig 6 1 Recommended calibration equipment...
Page 160: ......
Page 176: ...J400 RtADOUT BOARD 3B5 PLUG IN A READOUT...
Page 182: ...397 R E A D O U T B O A R D 10 6b READOUT BOARD...
Page 184: ...FIG 1 FRONT SWITCHES TYPE 3B5 AUTOMATIC PROGRAMMABLE TIME BASE...
Page 185: ...FIG 2 CHASSIS REAR 3 GS to TYPE 3B5 AUTOMATIC PROGRAMMABLE TIME BASE...
Page 186: ...OPTIONAL ACCESSORIES...