Eight Stage Boiler Control 258

Dem

Heat

System

Pmp

9 10

28

Sen

Com

Sw

UnO

29 30

Sen

Sup Out

Power

Minimum

120

°

F

Off

170

Boiler 

Differential

80

Power Supply:  24V 60Hz 5VA
Relay capacities: 24V 10A

Test

No power here

Maximum 24 volts

3

4

Stage

Sen

H1077

Date

S/N

221092
1234567

1

1

11 12

Stage

2

2

13 14

Stage

3

3

15 16

Stage

4

4

Power

Heat
Demand

Minimum

WWSD

Pump

Stage 1

Stage 2

Comb. Air

Stage 3

Stage 6

Stage 5

Stage 8

Stage 7

Stage 4

Menu

Item

Override

Setpoint

S

PRGM

TEMP

F C

Actual
Supply

Target
Supply

TIME

USE

AMPM

UNOCC

OVR

M T W T F S

OUTSIDE

ROOM

1
2

17 18 19 20 21 22 23

Air

Comb.

24 25

Stage

5

5

Stage

6

6

Stage

7

7

N/C

8

8

N/O

Com

M

tekmar
Zone
Control

Auto

Stage

1   2   3   4   5   6   7   8

Perm.
Demand

Ext. timer

Fixed last

Int. timer

Lo-Hi fire

Fixed lead

Off

1

2

3

4

5

6

7

8

9

External
Demand

Off

1

2

3

4

5

6

Stpnt

Reset

Rotate

8

- Data Brochure

Eight Stage Boiler Control 258

D 258

07/93

Terminal Plugs:

Power and out-

put connections

LEDs and

LCD screen;

display of times

& temperatures

Boiler
Differential
setting

Heating Curve
setting

Minimum
Supply setting

Terminal Plug:
Sensor and
timer inputs

Test button &
LED to test
main control
functions

System Pump

is on

Programming

buttons

Eight Stage Boiler Control 258

Power

Heat
Demand

Minimum

WWSD

Pump

Stage 1

Stage 2

Comb. air

Stage 3

Stage 6

Stage 5

Stage 8

Stage 7

Stage 4

Menu

Item

Override

Setpoint

Actual
Supply

Target
Supply

S

PRGM

TEMP

F C

TIME

USE

AMPM

UNOCC

OVR

M T W T F S

OUTSIDE

ROOM

1
2

Operating Mode

selector switches

Heating

is required

24Vac power

supply is on

Combustion air

damper is open

System is in

Warm Weather

Shut Down

Control is

maintaining

Minimum Supply

Input: Outdoor

Sensor 070

Included

Input: Supply
Sensor 071.  

Included

Input:

Unoccupied

signal.

Optional

Input:

tekmar 10K

Zone Control

 

Optional

Output: Turn on stages #1 to #8

Output: Open

Combustion Air

Damper

Input: Heat Demand
signal. 

Optional

Output: Turn

on System

Pump

24Vac power supply

Stages 1 to 8

are on

Outdoor Reset Strategy . . . . . . pg. 2

Error Messages . . . . . . . . . pg. 14

Sequence of Operation  . . . . . . pg. 4

Programming . . . . . . . . . . . pg. 15

Installation . . . . . . . . . . . . . . . . . pg. 7

Pre-Programed Schedules pg. 18

Settings . . . . . . . . . . . . . . . . . . . pg. 10

Technical Data . . . . . . . . . . pg. 19

Testing . . . . . . . . . . . . . . . . . . . . pg. 13

Limited Warranty . . . . . . . . pg. 20

The tekmar Eight Stage Boiler Control 258 is a microprocessor-based control which
regulates the supply water temperature from up to 8 boilers based on the outdoor air
temperature, and optionally, the indoor air temperature through a tekmar 10K Zone
Control.  The System pump is turned on when there is a Heat Demand and the outdoor
temperature is cool enough to require heat in the system.  When a combustion air
damper is used, it must be opened before the first boiler is fired.  The control has a
built-in setback timer and LCD screen to display temperatures and boiler running times.

Summary of Contents for Eight Stage Boiler Control 258

Page 1: ...mand Minimum WWSD Pump Stage 1 Stage 2 Comb air Stage 3 Stage 6 Stage 5 Stage 8 Stage 7 Stage 4 Menu Item Override Setpoint Actual Supply Target Supply S PRGM TEMP F C TIME USE AMPM UNOCC OVR M T W T...

Page 2: ...ugh water to keep the room temperature warm particularly during the colder weather If the Heating Curve selected is too high the supply water will be too hot for the conditions and the building will o...

Page 3: ...ntrol The effect of the Integral function can also be easily viewed by not allowing a rise in supply temperature when the control asks for more heat The displayed target temperature will show a slow b...

Page 4: ...allow Heating Curve operation System pump light on the system pump relay is on closing the contacts between terminals System Pmp 3 4 Comb air light on the combustion air relay is on closing the contac...

Page 5: ...e Occupied room temperature setting the control enters WWSD When switched into Unoccupied mode the UNOCC display element will replace the OCC display element and the control will switch from operating...

Page 6: ...e Stage and Comb air lights will be shut off with the boilers and combustion air damper The control will continue to cycle the boilers and combustion air damper to maintain the supply at the target te...

Page 7: ...lighter guage wire is too fragile and may also contribute too much resistance to the circuit Power should not be applied to any of the wires during this rough in wiring stage Step Four Electrical con...

Page 8: ...nals Heat Dem 5 and 6 When 24Vac is applied to these terminals the control will recognize a call for heat from the system DIP switch must be set to Reset If a 24Vac Setpoint Demand signal is used aqua...

Page 9: ...powered up the combustion air damper should operate If it does not come on check the circuit wiring for errors and ensure that it is powered up and the voltage is correct Check the devices in the cir...

Page 10: ...e Heating Curve use the following formula Outdoor air temperature Supply water temperature 50 10 30 1 10 12 10 F 23 C 110 43 70 21 70 21 90 32 210 99 170 77 150 65 130 54 190 88 3 6 3 0 2 4 2 0 1 6 0...

Page 11: ...w Domestic Hot Water boilers to be switched over to assist the heating boilers during peak load times Int timer switch The 258 control has an internal timer programmed using the LCD display and keypad...

Page 12: ...tback and delivering cold water to the boilers increased load Typically this will cause many or all of the boilers to be staged on with minimum delay which is the correct control action for the situat...

Page 13: ...ustion air damper will remain open After the 5 minutes the control will automatically exit the test routine and enter the normal operating mode If there is no Heat Demand the control will not allow a...

Page 14: ...ply temperatures and the LED system status lights display the operation of the various system components A competent troubleshooter can locate system faults without having to go any further than obser...

Page 15: ...tual Supply Target Supply F S TEMP OCC S M W T F T Auto Stage 1 2 3 4 5 6 7 8 Perm Demand Ext timer Fixed last Int timer Lo Hi fire Fixed lead Rotate Off 1 2 3 4 5 6 7 8 9 External Demand Off 1 2 3 4...

Page 16: ...ress or to change the day pointer PROGRAM MENU VIEWING Must be set to Int timer Auto 1 2 3 4 5 6 7 8 Perm Demand Ext timer Int timer Off 1 2 3 4 5 6 7 8 9 External Demand Off 1 2 3 4 5 6 Stpnt Reset P...

Page 17: ...button when the control is showing a fixed display Setpoint Actual Supply Target Supply F S TEMP S M W T F T OVR UNOCC Which mode is selected See page 3 Menu Item Override Menu Item Override Menu Item...

Page 18: ...nOcc 1 5 00 pm Occ 2 10 30 pm UnOcc 2 Friday 6 00 am Occ 1 8 30 am UnOcc 1 5 00 pm Occ 2 11 30 pm UnOcc 2 Saturday 8 00 am Occ 1 11 30 pm UnOcc 1 Null Occ 2 Null UnOcc 2 Schedule P 5 Day Time Temperat...

Page 19: ...when powered down for up to 10 years Battery backup Maintains clock operation for 24hrs when powered down Dial Switch Settings Heating Curve 0 4 to 3 6 Minimum Off 80 to 170 F Off 27 to 77 C Boiler D...

Page 20: ...antability and fitness for a particular purpose shall not extend beyond 24 months from the date of invoice or 12 months from the date of installation of the product whichever occurs first Replacements...

Reviews: