1592006207 XB570L GB r1.1 26.08.2015
XB570L
10
10. PARAMETERS
Hy Intervention differential for set point:
(0.1 to 12.0 res. 0.1°C or 1°F) always positive. Compressor cut-
IN is
SET+HY
. Compressor cut-OUT is when the temperature reaches the set point.
AC Anti-short cycle delay:
(0 to 30 min) minimum interval between the compressor stop and the following
restart.
PAU Time of stand by:
(0 to 60 min) after this time the controller restart the cycle.
PFt Maximum acceptable duration of power failure:
(0 to 250 min) if power failure duration is less than
PFt, the cycle restarts from the same point at which it was stopped otherwise the cycle restarts from the
beginning of the current phase.
Con Compressor ON time with faulty probe:
(0 to 255 min) time during which the compressor is active in
case of faulty thermostat probe. With
COn=0
compressor is always OFF.
CoF Compressor OFF time with faulty probe:
(0 to 255 min) time during which the compressor is off in
case of faulty thermostat probe. With
CoF=0
compressor is always active.
PROBES
rPOThermostat probe calibration:
(-12.0 to 12.0, res. 0.1°C or 1°F).
EPP Evaporator probe presence (not present in the XB350C):
(no / YES)
no:
not present (timed defrost);
YES:
present (end defrost).
EPO Evaporator probe calibration (not present in the XB350C):
(-12.0 to 12.0, res. 0.1°C or 1°F).
i1P Insert probe 1 presence:
(no / YES)
no:
not present;
YES:
present.
i1o Insert probe 1 calibration:
(-12.0 to 12.0, res. 0.1°C or 1°F).
i2P Insert probe 2 presence:
(no / YES)
no:
not present;
YES:
present.
i2o Insert probe 2 calibration:
(-12.0 to 12.0, res. 0.1°C or 1°F).
i3P Insert probe 3 presence:
(no / YES)
no:
not present;
YES:
present.
i3o Insert probe 3 calibration:
(-12.0 to 12.0, res. 0.1°C or 1°F).
rEM End cycle probe selection:
(iPt; rP) it sets which probe stops teh the cycle, thermostat probe or insert
probe:
iPt
=insert probe;
rPt
=thermostat probe.
NOTE: with rEM = rPt when the cycles are done by temperature, the rSi values are used as stop
of the cycle.
DISPLAY AND MEASUREMENT UNIT
CF Temperature measurement unit:
°C=Celsius; °F=Fahrenheit.
rES Resolution (for °C): in
=integer;
de
=with decimal point.
Lod Upper display visualization:
select which probe isshown by the upper display:
rP
=Thermostat probe
EP
=Evaporator probe
rEd Remote display, X-REP, visualization:
select which probe is displayed by the X-REP:
rP
=Thermostat probe;
EP
=Evaporator probe;
tiM
=cycle count down;
i1P
=insert probe 1;
i2P
=insert
probe 2;
i3P
=insert probe 3.
d1P Door switch input polarity (25-26):
(OP; CL) select if the digital input is activated by opening or closing
the contact.
OP
= opening;
CL
=closing.
odC Compressor and fan status when open door:
no
=normal;
FAn
=Fan OFF;
CPr
=Compressor(s) OFF;
F_C
=Compressor(s) and fan OFF.
doA Open door alarm delay:
(0 to 254min, 255=nu) delay between the detection of the open door condition
and its alarm signalling: the flashing message “dA” is displayed. If
doA=nu
the door alarm will be not
signalled.
dLc Stop count down of the running cycle with door open: Y
=count down is stopped with door opening;
n
=count down goes on with door open.
REGULATION
DIGITAL INPUTS
Summary of Contents for BLC10
Page 1: ...BLAST CHILLER FREEZER User Manual PT SL 49 61 EN FR IT ES 3 13 25 37...
Page 2: ...2...
Page 9: ...9 QUICK GUIDE For the daily use...
Page 13: ...REFROIDISSEURS CONG LATEURS RAPIDES Manuel d utilisation PT SL 49 61 FR IT ES 13 25 37...
Page 14: ...14...
Page 21: ...21 GUIDE RAPIDE Guide rapide quotidien...
Page 25: ...ABBATTITORI CONGELATORI Manuale d uso PT SL 49 61 IT ES 25 37...
Page 26: ...26...
Page 33: ...33 33 GUIDA RAPIDA Guida pratica quotidiana...
Page 37: ...ABATIDORES CONGELADORES Manual del usuario PT SL 49 61 ES 37...
Page 38: ...38...
Page 45: ...45 GU A R PIDA Gu a r pida diaria...
Page 49: ...PT SL 49 61 ABATEDORES DE TEMPERATURA CONGELADORES Manual do utilizador...
Page 50: ...50...
Page 57: ...57 GUIA R PIDO Guia r pido di rio...
Page 61: ...SL 61 HLADILNIK ZAMRZOVALNIKA ZA HITRO HLAJENJE ZAMRZOVANJE Navodila za uporabo...
Page 62: ...62...
Page 69: ...69 HITRI VODNIK Za dnevno uporabo...
Page 73: ...1592006207 XB570L GB r1 1 26 08 2015 XB570L 2 20 XB590L XB570L...
Page 94: ...1593006207 XB570L FR r1 0 26 08 2015 XB570L 2 24 XB590L XB570L...
Page 118: ...1591006207 XB570L IT r1 1 26 08 2015 XB570L 2 24 XB590L XB570L...
Page 141: ...1591006207 XB570L IT r1 1 26 08 2015 XB570L 25 24...
Page 142: ...1594006207 XB570L SP r1 0 26 08 2015 XB570L 2 20 XB590L XB570L...
Page 162: ...XB590L XB570L...
Page 177: ...1592006207 XB570L GB r1 1 26 08 2015 XB570L 16 20 3 12 2 MONTAGEM...
Page 184: ...1592006207 XB570L GB r1 1 26 08 2015 XB570L 2 20 XB590L XB570L...