Method 2 (LCD keypad only): Clock Off
To clock off, first press * to toggle the state so that Clock Off is displayed, then
key in the user PIN and press Enter.
8:59 03/02/18
Clock Off
Using Wiegand readers for time and attendance
Wiegand readers attached to DGPs on the NAC’s buses, the functionality is
determined by whether the reader is an IN reader or an OUT reader. IN readers
are Clock On readers and OUT readers are Clock Off readers.
Badging a card on a Clock On card reader automatically clocks you on. Badging
a card on a Clock Off card reader automatically clocks you off.
Macro events
Refer to the following tables:
Table 8: Door macro event descriptions below
Table 9: Other macro event descriptions on page 101
Table 8: Door macro event descriptions
Name
Description
Input
Output
Door access denied
Door access has not been allowed
Yes
No
Door access granted Door access has been allowed
Yes
No
Door access granted
1st badge
Door access has been granted when badged once
Yes
No
Door access granted
2nd badge
Door access has been granted when badged twice
Yes
No
Door access granted
3rd badge
Door access has been granted when badged three times
Yes
No
Door access granted
in button
Door access has been granted and IN button pressed
Yes
No
Door access granted
out button
Door access has been granted and OUT button pressed
Yes
No
Door access granted
traced
Door access has been granted to a user with trace On
Yes
No
** Door anti-
passback
Anti-passback is active
Yes
No
Door area secure
Area assigned to door is secure
Yes
Yes
*** Door buzzer
Buzzer output is active
Yes
Yes
Door disabled
Door is disabled completely (from keypad or computer)
Yes
Yes
** Door dual custody
inside
Dual Custody
access is required at the "IN” reader
Yes
Yes