![TECOM TS1066 Programming Manual Download Page 97](http://html1.mh-extra.com/html/tecom/ts1066/ts1066_programming-manual_1072587097.webp)
If you right-click on a DGP
(including the NAC’s own DGP node), the following
options appear in the context menu:
Isolate
– isolates the DGP.
De-isolate
– de-isolates the DGP.
Battery test
– starts a timed battery test.
Cancel test
– cancels an undergoing battery test.
Update status
– updates the icon and description to the current status of
the DGP.
Diagnostics
– opens a window showing detailed diagnostics for the NAC,
including its power supply voltage and current, battery status, and state of
inputs.
Note:
This option only appears if the DGP node represents the NAC itself.
Upgrade firmware
– allows the operator to upgrade the firmware on the
DGP. Refer to the relevant manual.
Note:
This option only appears if the DGP node represents a DGP
assigned to the NAC and not the NAC itself.
If you right-click on a RAS, the following options appear in the context menu:
Isolate
– isolates the RAS.
De-isolate
– de-isolates the RAS.
Update status
– updates the icon and description of the RAS to its
current status.
Configuring door schedules
Up to 100
door schedules
can be programmed in the NAC, allowing for very
flexible door locking and unlocking schedules.
For more information on door schedules,
see the “Overriding door state” section