1.2 – COMMANDS ON THE PANEL
Upward direction key used for moving the cursor inside the upper parameter.
Downward direction key used for moving the cursor inside the lower parameter.
This key is used for increasing the value of a numeric parameter or for changing the
status of a parameter.
This key is used for decreasing the value of a numeric parameter or for changing the
status of a parameter.
WELD-NO WELD Key.
In WELD position (LED switched on) the control unit runs the programmed welding
cycle. In NO-WELD position (LED switched off), the control unit runs the
programmed cycle without welding current circulation keeping all the time
parameters unchanged.
Use the WELD/NO WELD function to carry out test cycles without welding current. Welding current is enabled or
disabled by means of the button shown above. When the lamp is on, the control unit is set to WELD and carries
out the standard welding cycles. When the lamp is off, the control unit is set to NO WELD: complete test cycles
will be carried out, without welding, while maintaining all the time parameters.
1.3 – PANEL LEDs
START
INIZIO CICLO
If on, this LED indicates that the cycle start command from the button of handle 1
(connected to XS10) is activated.
START 2
INIZIO CICLO 2
2
If on, this LED indicates that the cycle start command from the button of handle 2
(connected to XS11) is activated.
AUX
AUSILIARIO
When this warning light turns on, it means that the stop command by means of
pressure only, through the AUX input, is activated. As a rule, it is activated by the
"PRESSURE ONLY" selector.
CURRENT
CORRENTE
If on, this LED indicates that the control unit is generating the SCR trigger impulses.
SOLENOID VALVE 1
1
It indicates that the solenoid valve executing the main cycle is activated.
SOLENOID VALVE 2
2
It indicates that the solenoid valve driving the double stroke is activated.