S.p.A.
TE470/TE480 Instruction
Manual
2.6 - SETUP MENU
This menu contains the parameters of certain special and configuration functions of the machine on which the
control unit works.
Keep in mind that only skilled personnel are permitted to edit the following parameters to
prevent damage to people or equipment.
In order to access this menu, press buttons
and
at the same time for about one second. Once inside the
menu, the different parameters are shown in sequence.
TOTAL STEPS 1
SPOTS 1 00000
In order to select the parameters, use buttons
and
; to change, use buttons
and
to increase and
decrease the value displayed.
After 8 seconds of inactivity, the control automatically exits the programming procedure and allows the process
to be run.
SETUP MENU PARAMETERS TABLES
PARAMETER DESCRIPTION
VALUE
RANGE
TOTAL STEPS
Number of segments per stepper function
1 - 7
SPOTS 1
Number of spots of the first segment
0 - 10000
INCREMENT 1
Increase percentage of the first segment
0 - 60%
SPOTS 2
Number of spots of the second segment
1 - 5000
INCREMENT 2
Increase percentage of the second segment
1 - 60%
SPOTS 3
Number of spots of the third segment
0 - 5000
INCREMENT 3
Increase percentage of the third segment
1 - 60%
SPOTS 4
Number of spots of the fourth segment
0 - 5000
INCREMENT 4
Increase percentage of the fourth segment
1 - 60%
SPOTS 5
Number of spots of the fifth segment
0 - 5000
INCREMENT 5
Increase percentage of the fifth segment
1 - 60%
SPOTS 6
Number of spots of the sixth segment
0 - 5000
INCREMENT 6
Increase percentage of the sixth segment
1 - 60%
SPOTS 7
Number of spots of the seventh segment
0 - 5000
INCREMENT 7
Increase percentage of the seventh segment
1 - 60%
SPOT DRES.
No. of spots for dressing
0 - 999
FIRST INSERT
First insertion delay
1 - 99%
STOP SPOTS
Number of out-of-limit spots before stopping the unit
0 - 9
LANGUAGE
Language of displayed messages
ITA – ENG – ESP –DEU –
FRA – UNG – POR – SWE
SERIAL COM.
Serial communication
485 - OFF
ADDRESS
Network address
01 - 31
PROP. VALVE
Proportional valve
ON – OFF
PRESS. RATIO
Proportional valve bar/volt ratio
0.2 – 2.0
HANDLE
Describes the number or type of handles connected to the
TE470/TE480
1 – 2 – 4PRG
N.PRG ADJ 1
Number of program associated with ADJUSTMENT 1
01 – 63
N.PRG ADJ 2
Number of program associated with ADJUSTMENT 2
01 – 63
N.PRG ADJ 3
Number of program associated with ADJUSTMENT 3
01 – 63
N.PRG ADJ 4
Number of program associated with ADJUSTMENT 4
01 – 63
22/52