CHAPTER 7 - HANDLES DESCRIPTION
Below are briefly described the characteristics of the handles that the TE470/TE480 can manage and be fitted
with.
Set the HANDLE parameter inside the SETUP MENU by indicating the number or type of handle that is
connected to the control unit.
Handle with 2-position selector without double stroke or with double stroke
1. Cycle start control button (START input)
2. Safety function button (CHK input)
3. PRESSURE ONLY function control button (AUX input)
4. Switch for calling the second work program ADJUSTMENT 2 (RIC2 input)
5. Button for the "wide opening" function (OPEN input) when the double stroke function is present
Set the HANDLE parameter to 1 when only one handle is connected to input XS10. In this configuration, the
programs selected in ADJUSTMENT 1 and 2 will be called.
Set the HANDLE parameter to 2 when 2 handles are connected: one to input XS10 and the other to input XS11.
In this configuration, even the programs selected in ADJUSTMENT 3 and 4 will be called through the handle
connected to XS11.
Handle with 4-position selector without double stroke or with double stroke
1. Cycle start control button (START input)
2. Safety function button (CHK input)
3. PRESSURE ONLY function control button (AUX input).
4. Commutator for calling four work programs: ADJUSTMENT 1, 2, 3 and 4 (RIC2 and RIC3 inputs)
5. Button for the "large opening" function (OPEN input) when the double stroke function is present
This type of handle can be connected only to the XS10 input of the cover and in this case you must set the
HANDLE parameter to 4PRG.