Instruction Manual
TE470/TE480
S.p.A.
AUTOMATIC
By programming the value of the STROKE parameter to AUTOMATIC, the operator adjusts the control unit for
the automatic stroke. This mode is used during the automatic cycle mode (PAUSE parameter other than 0). It
allows carrying out consecutive welding cycles with the short stroke but starting from a long stroke work
condition, useful, for example, for inserting the welding gripper in the workpiece to be welded.
When the welding cycle starts, the control unit activates solenoid valve EV2 (that moves the electrode from
position A to position B) and carries out the programmed first squeeze time (SQUEEZE 1) before activating EV1.
After having carried out the first weld of the automatic cycle, solenoid valve EV2 is not deactivated and the first
squeeze time (SQUEEZE1) is ignored during the subsequent welds. This continues until the operator releases
the cycle start control that ends the welds sequence; the control unit deactivates both EV1 and EV2, which
moves the electrodes back to the wide opening position. If the double stroke had already been activated before
the welding had begun, the control unit does not carry out the first squeeze time.
41/52