Instruction Manual
TE470/TE480
S.p.A.
CHAPTER 2 - CONTROL UNIT PROGRAMMING
2.1 – WELDING CYCLE PARAMETERS PROGRAMMING MENU
Press buttons
and
simultaneously for at least one second to program the welding cycle parameters.
Once inside the menu, the control unit automatically exits from the programming procedure after 8 seconds of
inactivity and allows the process to be run.
The first choice to make is the number of the programme. Use buttons
and
to change this value.
ADJUSTMENT 1
PROGRAM N. 01
After having chosen the number of the programme, select the parameters that make up the program through
buttons
and
and set the required value each time, using buttons
and
.
The parameters are identified by a letter (from A to C) or a number (from 1 to 22).
The display shows the following data:
ADJ1 PRG01 PRM07
WELD 1 08.0 ~
1
2
3
4
5
1. ADJ1
Indicates the ADJUSTMENT associated with the programme. According to the PRG program number selected
beforehand, the ADJ will assume the value associated inside the SETUP menu.
It can have the following values:
ADJ1 (ADJUSTMENT 1), ADJ2 (ADJUSTMENT 2), ADJ3 (ADJUSTMENT 3), ADJ4 (ADJUSTMENT 4) or ADJ–
when the selected program number is not associated with an ADJ (also see description inside the SETUP
menu).
2. PRG01
Indicates the selected program number (e.g.: PRG01 = program number 1) and its value is between 01 and 63.
3. PRM07
Identifies the selected parameter (e.g.: PRM07 = parameter number 7) with a value that includes a letter (from A
to C) or a number (from 1 to 22).
4. WELD 1
Indicates the name of the selected parameter (e.g.: WELD 1).
5. 08.0 ~
Indicates the value of the selected parameter (e.g.: 08.0 cycles).
Change the value of the parameters using buttons
and
to increase and decrease the displayed value.
Then set the next parameters using buttons
and
.
In this manner the required parameters are set to the value needed to carry out the weld. Keep in mind that no
key is to be pressed to confirm the set datum that is stored automatically after the adjustment.
When the programming operations are accomplished, wait until the control unit ends the programming phase;
this takes place automatically after 8 seconds of inactivity.
11/52