Technosoft 2013
55
iPOS360x MX Technical Reference
2. If
BR
BRAKE
NOM
CY CLE
d
BR
P
U
I
t
t
P
2
2
2
either
the braking power must be reduced (see Remark 1)
or t
CYCLE
–
the time interval between braking cycles must be increased
WARNING!
THE BRAKE RESISTOR MAY HAVE HOT SURFACES
DURING OPERATION.
3.4.12.
Serial RS-232 connection
3.4.12.1 Serial RS-232 connection
Figure 3.21.
Serial RS-232 connection
3.4.12.2 Recommendation for wiring
a) If you build the serial cable, you can use a 3-wire shielded cable with shield connected to
BOTH ends. Do not use the shield as GND. The ground wire (pin B1 of J1) must be included
inside the shield, like the 232Rx and 232Tx signals
b) Always power-off all the iPOS360x supplies before inserting/removing the RS-232 serial
connector
c) Do not rely on an earthed PC to provide the iPOS360x GND connection! The drive must be
earthed through a separate circuit. Most communication problems are caused by the lack
of such connection
3.4.13.
CAN-bus connection
Summary of Contents for iPOS360x MX
Page 2: ......
Page 4: ......
Page 13: ... Technosoft 2014 XI iPOS360x MX Technical Reference This page is empty 1 Safety information ...
Page 69: ... Technosoft 2013 57 iPOS360x MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 114: ... Technosoft 2013 102 iPOS360x MX Technical Reference This page is empty ...
Page 115: ......
Page 116: ......