Technosoft 2013
93
iPOS360x MX Technical Reference
No_steps
–
is the number of motor steps per revolution
No_µsteps
–
is the number of microsteps per step. You can read/change this value in the “Drive
Setup” dialogue from EasySetUp.
Tr
–
transmission ratio between the motor displacement in SI units and load displacement in SI
units
T
–
is the slow loop sampling period expressed in [s]. You can read this value in the “Advanced”
dialogue, which can be opened from the “Drive Setup”
6.4.4.
Step motor open-loop control. Incremental encoder on load
The internal jerk units are load encoder counts / (slow loop sampling period)
3
. The transmission is
rotary-to-rotary. The correspondence with the load jerk in SI units is:
]
IU
[
Jerk
_
Load
T
lines
_
encoder
_
No
]
SI
[
Jerk
_
Load
3
4
2
where:
No_encoder_lines
–
is the rotary encoder number of lines per revolution
T
–
is the slow loop sampling period expressed in [s]. You can read this value in the “Advanced”
dialogue, which can be opened from the “Drive Setup”.
6.4.5.
Step motor closed-loop control. Incremental encoder on motor
The internal jerk units are motor encoder counts / (slow loop sampling period)
3
. The correspondence
with the load jerk in SI units is:
]
IU
[
Jerk
_
Motor
T
Tr
lines
_
encoder
_
No
]
SI
[
Jerk
_
Load
3
4
2
where:
No_encoder_lines
–
is the motor encoder number of lines per revolution
Tr
–
transmission ratio between the motor displacement in SI units and load displacement in SI
units
T
–
is the slow loop sampling period expressed in [s]. You can read this value in the “Advanced”
dialogue, which can be opened from the “Drive Setup”.
Summary of Contents for iPOS360x MX
Page 2: ......
Page 4: ......
Page 13: ... Technosoft 2014 XI iPOS360x MX Technical Reference This page is empty 1 Safety information ...
Page 69: ... Technosoft 2013 57 iPOS360x MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 114: ... Technosoft 2013 102 iPOS360x MX Technical Reference This page is empty ...
Page 115: ......
Page 116: ......