Technosoft 2014
11
iPOS360x MX Technical Reference
Figure 2.7.
Brushless AC linear motor with linear Hall signals.
Position / speed / torque control.
8. Position, speed or torque control of a
DC
brushed
rotary motor
with an
incremental
quadrature encoder
on its shaft. Scaling factors take into account the transmission ratio
between motor and load (rotary or linear). Therefore, the motion commands (for position,
speed and acceleration) expressed in SI units (or derivatives) refer to the load
1
, while the
same commands, expressed in IU units, refer to the motor.
Figure 2.8.
DC brushed rotary motor. Position / speed / torque control.
Quadrature encoder on motor.
9. Open-loop control of a 2 or 3-phase
step motor
in position or speed. Scaling factors take
into account the transmission ratio between motor and load (rotary or linear). Therefore,
the motion commands (for position, speed and acceleration) expressed in SI units (or
derivatives) refer to the load, while the same commands, expressed in IU units, refer to the
motor.
1
Motion commands can be referred to the motor by setting in EasySetUp a rotary to rotary transmission with ratio 1:1