The control
The control block diagram is as follows:
E2 = UNITY (HK)
receives the
Emergency 2
signal.
•
When the system is NOT in emergency the signal is +12V.
•
When you press the EMERGENCY signal goes to GND.
E1 = ALE-MET
(LK)
receives the
Emergency 1
signal.
•
When the system is NOT in emergency the signal is on GND.
•
When you press the EMERGENCY signal goes to +12V.
E1 = ALEWin (LK)
receives the
Emergency 1
signal.
•
When the system is NOT in emergency the signal is GND (pin 9).
•
W When you press the EMERGENCY signal goes to +12V.
Driver Note (Low Kit):
•
ALE MET and ALEWin: Until the two drivers will coexist, the ALEWin driver will
behave as the ALE-MET. Active Emergency low level (GND).