JOG NOW : Service & maintenance manual - rev. 6.2
Page 6.36
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Place the tester probes across pins
1
and
2
on the connector
HD4
of the receiver. The
measured value should be +5Vdc.
(2)
As at step
(1)
but on pins
1
e
5
on
CN9
connector (
ARM Board
) or on
CN31
connector (
CPU
Board
); of the
CU135
cable
.
(3)
Check the correct display SW version, according to the “EXCITE SW SMART TABLE” you
can find in
TG Direct
,“NEWS” section.
Check the grounding of the
HR/HS Receiver Board
, measuring the resistance value between:
1.
The ground fast on of HR/HS Receiver Board and the ground node on the Power supply
box of the machine;
2.
The ground node of the power entry module and the main wall socket.
The measured value should be approximately lower than 1Ω (Ohm).
Check finally the grounding of the main wall socket, measuring that the following voltages are
present:
P – N (phase – neutral) = 220Vac / 110Vac
P – G (phase – ground) = 220Vac / 110Vac
N – G (neutral – ground) = 0Vac
(4)
Check if the receiver has been correctly mounted on the machine, as detail at paragraph: 7.6.1.
“HS/HR Receiver (Chest Belt/Hand Sensor)”.
If you replace CPU/ARM Board, check that its SW version is updated, otherwise install
the last version.
Summary of Contents for Jog Now Excite+ 700
Page 2: ......
Page 4: ...JOG NOW Excite Service maintenance manual rev 6 2...
Page 29: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 2 17 UNITY Version...
Page 31: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 2 19 UNITY Version...
Page 186: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 8 6 Page intentionally left blank...
Page 222: ...JOG NOW Excite Service maintenance manual rev 6 2 Pagina 12 2 Blank page...
Page 224: ...JOG NOW Excite Service maintenance manual rev 6 2 Pagina 13 2 Blank page...
Page 226: ......
Page 227: ......