LOW KIT
3.21.1.
ALE
MET
CE
DRIVER
This is the electronic device that receives the line voltage and, through a PFC module, it rectifies the
voltage to the 400Vdc used to generate the 3 phase voltage for the belt motor. It generates the DC
voltages to power up all the other devices of the machine.
It’s the device that acts as an interconnection hub for the main components of the lower assembly,
and serves as the point of connection with the display. In fact:
it supplies the +12Vdc voltages to the display;
it supplies the tread belt motor with a variable-frequency sinusoidal voltage: varying the
frequency varies the speed of rotation of the motor, and consequently the speed of the tread
belt;
it exchanges, over the RS-485 serial link to the Display Board, the commands for controlling
the tread belt and elevation motors;
it exchanges, over the RS-485 serial link to the Display Board, the commands for viewing and
configuring the inverter parameters;
it exchanges, over the RS-485 serial link to the Display Board the commands for viewing the
errors logged by the inverter.
From the outside the following indicator LEDs are visible:
LED NAME
COLOUR
DESCRIPTION
H6
GREEN
+5Vdc (if ON proper functioning)
H3
GREEN
+12Vdc (if ON proper functioning)
H4
GREEN
+24Vdc (if ON proper functioning)
H5
BLUE
400Vdc (if ON proper functioning)
The board includes the following indicator LEDs visible when the driver cover is removed:
LED NAME
COLOUR
DESCRIPTION
ALARM
RED
If ON indicates that the Driver has detected an error (EdC)
when it was moving the elevation motor. This LED stay ON
for about 1 second and then goes OFF.
EN_UP
GREEN
if ON indicates that the motor has received the supply
voltage for movement in the upward direction
EN_DOWN
RED
if ON indicates that the motor has received the supply
voltage for movement in the downward direction
TACHO
GREEN
functioning of elevation motor encoder: if blinking, indicates
that the board is receiving the pulses from the encoder
DWN_SW
GREEN
status of Limit switch contact: if ON indicates that the
microswitch is pressed
Summary of Contents for Jog Now Excite+ 700
Page 2: ......
Page 4: ...JOG NOW Excite Service maintenance manual rev 6 2...
Page 29: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 2 17 UNITY Version...
Page 31: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 2 19 UNITY Version...
Page 186: ...JOG NOW Excite Service maintenance manual rev 6 2 Page 8 6 Page intentionally left blank...
Page 222: ...JOG NOW Excite Service maintenance manual rev 6 2 Pagina 12 2 Blank page...
Page 224: ...JOG NOW Excite Service maintenance manual rev 6 2 Pagina 13 2 Blank page...
Page 226: ......
Page 227: ......