JOG NOW : Service & maintenance manual - rev. 6.2
Page 6.26
"GRADIENT NOT
WORKING" MESSAGE
ON THE DISPLAY
Check the P09
parameter is
correctly set
1
2
Replace the
limit switch
NO
NO
Set P09 = 0,
turn of f and on the machine.
The elev ation changes
(elev ation enabled)?
YES
Is the limit switch
working properly ?
YES
Check that during the
mov ement, the pulse signals
are present on the J7
connector of the Driv er.
Replace the Driv er
and set again the
P09 = 15
NO
Check if the tension reaches
the elev ation motor during the
reset procedure
NO
Replace the elev ation
motor and set again
the P09 = 15
YES
Replace the Driv er
and set the P09 = 15
NO
4