5
Positioning of different facilities
CAUTION:
For trouble-free operation of the machine it is not necessary for the machine to be anchored to the floor, nor
are any special measures necessary to limit vibration.
A number of important points should, however, be borne in mind:
-
Leave a space of at least 50 cm around the machine. This is indispensable to ensure
maintenance work can easily be carried out on the machine.
-
Connect the machine to the electricity supply at point
F
with a cable coming from above to avoid
any danger of crushing underfoot. For power data, please see page
7
.
-
Make sure the floor is strong enough to take the weight of the machine.
-
Check the machine is stable by making sure that the four legs are firmly resting on the floor.
-
Connect the machine to the water supply at points
D
and
E
with firmly fitted piping which will
withstand a minimum pressure of
10 Bar
. For data regarding consumption please see page
8
.
-
Connect the machine to the compressed air at point
AC
. For data regarding consumption
please see page
9
.
Dimensions of the machine:
A
Width in mm
B
Depth in mm
C
Height in mm
Weight
Kg.
700
1050
1480
460