Technical specifications: FREEZER 200/1
Refrigerator compressor
Copeland SKROLL- kW 5
Copeland semi-airtight HP 4
– kW 3
Dorin semi-airtight HP 4
– kW 3
Refrigerating gas
Freon R404 (quantity 4 kg.)
Dasher stirrer motor
900 r.p.m.
– 3 Hp – 2,2 kW
Condensation
Water
Pump motor
1400 r.p.m.
– 1 Hp – 0,75 kW
Magnetothermals calibration
200 V
50/60HZ
220 V
50HZ
220 V
60HZ
380 V
50HZ
440 V
60HZ
415 V
50HZ
Refrigerating compressor A
20
20
12
12
12
Dasher stirrer motor A
9,5
9,5
6
6
6
Pump motor A
3,5
3,5
2,2
2,2
2,2
Electric system fuses
200V and 220V
380V and 415V
Primary transformer F2
n°2 d. 5 x 20 2A quick type
n°2 d. 5X20 2A quick type
Secondary transformer
n°1 d. 5 x 20 8A delayed type
n°1 d. 5 x 20 8A delayed type
Fan and resistance compressor
protection
n°2 d. 5 x 20 2A quick type
n°2 d. 5 x 20 2A quick type
Pressure switches calibration-low/high pressure
Set in values
Low pressure threshold value
0,2 Bar
High pressure threshold value
20 Bar
Differential
0,7 Bar
Oil pressure switch (where equipped)
Calibration values: 0,7
– Differential 0,2 Bar
REFRIGERATOR SYSTEM WORKING TEMPERATURES
Condensation (high pressure)
Evaporation (low pressure)
+35°
-28/-32°C
Value viscosity
220V
380/415V
9 A.
6 A.
The machine is delivered with the above-mentioned values and calibrations performed in factory.
TECHNOGEL S.p.A. IS NOT RESPONSIBLE FOR DAMAGES TO OBJECTS AND/OR
PERSONNEL CAUSED BY MODIFICATIONS TO THE PRE-SET VALUES, OR FROM USING
FUSES THAT HAVE INCORRECT CHARACTERISTICS AND SIZE, OR IN ANY
CASE DIFFERENT FROM THOSE PRESCRIBED
.