6-41
6. DIAG. TEST OPERATION
EO18-33006
6.3.19 Ribbon Motor Drive Voltage Fine Adjustment
6.3 PARAMETER SETTING MODE
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. Max. fine adjustment -15 steps = Key fine adjustment value (-15 steps)+PC fine adjustment
value (-15 steps)
When the value reaches the maximum, the value remains unchanged even if the subsequent
fine adjustment is performed.
3. A changed motor voltage value is stored in memory by pressing the [PAUSE] key.
4. One step corresponds to 5% of the standard voltage and up to 75% of the voltage can be
decreased.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key 20 times.
Press the [FEED] or
[RESTART] key to fine
adjust the rewind motor
voltage. (See NOTE 1.)
Press the [FEED] or
[RESTART] key to fine
adjust the feed motor
voltage. (See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
(See NOTE 3.)
(Ribbon feed motor voltage fine
adjustment)
(Ribbon take-up motor fine
adjustment)
[FEED] key:
Pressing the [FEED] key one
time is a -1 steps change, up to
-15 steps. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +1 steps change, up to
0 steps. (See NOTE 2.)
[FEED] key:
Pressing the [FEED] key one
time is a -1 steps change, up to
-15 steps. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +1 steps change, up to 0
steps. (See NOTE 2.)
Press the [PAUSE] key.
Continued on Section 6.3.20
Strip Wait Status Selection.
< 1
D I A G N O S T I C V
>
1 . 0 A
R I
B O N A D J < F W D >
B
- 1 0
< 2
P A R A M E T E R S E T
>
R I
B O N A D J < B A K >
B
- 3