6-29
6. DIAG. TEST OPERATION
EO18-33006
6.3.8
Baud Rate Selection
6.3 PARAMETER SETTING MODE
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key 9 times.
Select baud rate with the
[FEED] key or [RESTART]
key. (See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.9
Data Length Selection.
38400 BPS
19200 BPS
9600 BPS
4800 BPS
2400 BPS
< 1
D I A G N O S T I C V
>
1 . 0 A
S P
E D
9 6 0
E
0 B P S
< 2
P A R A M E T E R S E T
>
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. A changed baud rate is stored in memory by pressing the [PAUSE] key.