background image

12

TEC-67398-2

 

Technical description Prizrak-5S BT

Immobilizer 

adjustments

1st step. Interfacing the immobilizer with a vehicle

All vehicles compatible with the immobilizer system are devided into functional groups. Each group is devided 

into subgroup. Groups and subgroups are endowed with a special number (https://int.tecel.ru/). Interfacing the 

immobilizer with a vehicle means vehicle group and subgroup identification. 

The interfacing procedure may be carried out as follows:

• 

via a laptop or a PC.

• 

automatically – by connecting the immobilizer to a vehicle’s harness.

• 

manually – by using the programming menu of the immobilizer.

Interfacing via a PC

A vehicle make, model and other settings of the Immobilizer system can be configured using a PC with the al

-

ready installed software TECprog2. This intefacing method helps shorten the installation time and avoid possible 

mistakes in programming.

Automatic interfacing

The immobilizer identifies an appropriate group and subgroup after connecting it to the vehicle's CAN-bus and 

power source, and performing some simple actions (the typical simple actions are: cycling the ignition on/off and 

locking/unlock ing a vehicle using the original remote). An interfacing procedure for each vehicle make and model is 

described in the Integrator (https://int.tecel.ru). After carrying out all necessary actions you have to make sure that 

the group and subgroup have been identified correctly. The identified group and subgroup is indicated by beeps (a 

group number - pause, a subgroup number-pause).

If a vehicle group is a two-digit number – then every figure will be indicated separately. For example, the group 

35 and the subgroup 2 will be indicated as follows: 3 long beeps – 1 sec pause, 5 long beeps – 2 sec. pause, 2 

short beeps – 4 sec. The module will indicate the detected group and subgroup circularly 3 times.

Manual interfacing

This interfacing method might be necessary only in exceptional cases. A group and subgroup programming is 

carried out with the built-in programming (reset) button. Make sure no group and subgroup is already programmed 

before you start the procedure, the CAN-bus must not be connected as well.  If within 60 seconds the programming 

button is not pressed the module will automatically abort the programming process.

Manual interfacing is carried out as follows:

1. 

Power up the immobilizer, wait until it starts emitting intermittent beeps.

2. 

Not later than in ten seconds after that press the programming button 10 times to enter the «Menu 10». 

The module will emit 3 beeps to confirm that the appropriate programming menu has been successfully 

selected.

3. 

Press the programming button 1 time in order to enter the option №1 «Vehicle model». The immobilizer will 

indicate the selected option number by a repeating series of 1 beep.

4. 

Press and release the programming button the number of times that corresponds to a group number you 

wish to program (refer to the Integrator).

5. 

Then enter a subgroup number by pressing and releasing the programming button the appropriate number 

of times (refer to the integrator).

• 

In case if a vehicle group consists of a two-digit number, enter the first didgit of the group number, wait 

for two seconds and then enter the second digit of the group number. The immobilizer will emit a series of 

beeps which corresponds to a group number. 

Make sure you have programmed the correct vehicle model by listening to the emitted beeps:

• 

press and release the programming button 1 time if everything is correct, The immoblizer will stop beeping 

the vehicle model is now programmed.

• 

press and release the programming button 2 times if there is a mistake. Repeat the programming process 

from the step №4.

Summary of Contents for Prizrak 5S/BT

Page 1: ...PROTECTION AGAINST PROFESSIONAL CARJACKING IMMOBILIZER TECHNICAL DESCRIPTION...

Page 2: ...with a vehicle 12 2nd step Selecting and programming vehicle buttons 13 3rd step Configuring the Immobilizer features 13 Configuring the immobilizer hardware functions 14 Configuring the programmable...

Page 3: ...g the user s se cret Bluetooth code The Installer mode of the application was specially designed for this purpose The barcode located on the plastic card supplied with the device should be used to pai...

Page 4: ...rd lights and driver warning beeps will activated for 15 seconds Herewith AntiHiJack allows to start the vehicle s engine but prevents driving the vehicle according to the same algorithms as the Immob...

Page 5: ...scratch off the protective film of the Bluetooth code however it is possible to test the immobilizer performance after installing it by using a temporary code the code to register a smartphone as the...

Page 6: ...rry out an authentication procedure The immobilizer will emit the confirmatory trill indicating that the authentication is successful 3 Press and release the programming button 12 times the immobilize...

Page 7: ...vehicle has travelled 10 km after installing the system the authentication method can only be changed after entering the secret PUK code located on the plastic card supplied with the device Futhermor...

Page 8: ...ur installation technician to find out the list of available buttons for your vehicle Enter PIN code While entering one of the PIN digits keep in mind that pressings duration and pauses be tween figur...

Page 9: ...ce mode Quickly engaging maximum security Two circuit security mode increases the anti theft possibilities of the immobilizer system in case if the tag is stolen or lost Engage the second security cir...

Page 10: ...ock control The system s anti thieft capabilities may be improved by installing an additional electro mechanical hood lock and programming the alarm to latch the hood when arming the vehicle and to un...

Page 11: ...nt is described in the Table 3 Connectors pin numeration is shown in figure 1 Inputs outputs adjustment is carried out through the programming menu see section Hardware functions configuration 12 7 1...

Page 12: ...pause 2 short beeps 4 sec The module will indicate the detected group and subgroup circularly 3 times Manual interfacing This interfacing method might be necessary only in exceptional cases A group a...

Page 13: ...corresponding po larity and assign the feature 6 refer to the Table 7 to the programmable inputs These buttons may be used as the programming button or for entering a PIN code even if the resistive o...

Page 14: ...n It is also possible to assign to these inputs any feature listed in the Table 7 if the option 6 is configured for the value 2 7 Hazard lights control method 4 1 by connecting to a pulse hazard light...

Page 15: ...short beeps 25 two long and 5 short beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t b...

Page 16: ...yellow 9 wires configuration CAN bus or Output 1 1 data bus CAN2 2 programmable output 5 Brown wire 3 function configu ration This wire function is dependant on the value of the option 4 Data bus CAN2...

Page 17: ...lowed to en ter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after the installation and the default PIN code hasn t been changed The immobilizer system will automatic...

Page 18: ...monitoring If it is not possible to read the Ignition status data out of the vehicle s CAN bus for exam ple when a vehicle s specific electrical circuits are being interrupted then this immobilizer i...

Page 19: ...en only those doors you may do it beforehand that are supposed to be indicated on that output the doors you don t want to be indicated should be closed Apply the brake pedal again and keep it pressed...

Page 20: ...ed if the engine is running and the vehicle s speed is less than 15 km h Yes 18 Rear parking sensors control power supply A constant level signal is formed if the engine is running the gear lever is s...

Page 21: ...immobilizer is interfaced with a vehicle but also may be programmed manually if needed Yes 34 CDL unlocking alternative control A pulse is formed to unlock the power door locks with a double wire cont...

Page 22: ...on hereinafter referred to as PB The immobilizer emits audible signals hereinafter beeps to indicate the current state of a setting being programmed In case if the option number or the option value co...

Page 23: ...system s memory 5 To delete the smartphone tags from memory still hoding the brake pedal down press and release the programming button 1 time the confirmation trill followed after that signifies that...

Page 24: ...ll immobilizer features to the default settings In case if the immobilizer is not installed on a vehicle The reset can be carried out in 3 ways 1 Using the built in button provided that the factory PI...

Page 25: ...ing procedure for a certain car may be found out in the Integrator https int tecel ru 5 Change the factory PIN code 6 Inform the vehicle s owner which particular button has been assigned as the progra...

Page 26: ...ure allows to quickly analyze the data available on the vehicle s CAN bus and adjust connection scheme if required The built in LED is used for indication check The immobilizer connection diagram The...

Page 27: ...rizrak 5S BT Mark in the picture the immobilizer ele ments installation place This may help to quickly find them later The immobilizer elements installation scheme in a vehicle Keep this scheme out of...

Page 28: ...ble beeps hereinafter beeps It is allowed to enter PIN code 2 with the programming button if a vehicle hasn t yet travelled 10 km after installing the system and the default PIN code hasn t been chang...

Page 29: ...ation adjustment 3 Output 4 1 alert warning signals to siren 2 en gine locking normally closed NC relay control 3 programmable output refer to the option 8 4 electromechanical hood lock latching 8 The...

Page 30: ...luetooth using an adapter TEC prog USB Bluetooth and follow the displayed instructions Cancelling registration if the main Immobilizer module is not available 1 Disconnect the module from power 2 Conn...

Page 31: ...1 Quick reference card 1 Owner s guide 1 Warranty card 1 Wiring diagram 1 Packing 1 Technical specifications and operating conditions Parameter Value Power supply voltage V 9 15 Maximum current drain...

Page 32: ...www tecel ru...