User’s manual
Name
Description
Min
Max Default
UM
Scale
direction of rotation
PRC_SPD_THR_GAIN_CHG P44 - End speed for speed PI gain change
0.0
100.0
0
% MOT_SPD_MAX 163.84
START_SPD_REG_KP
P45 - KpV initial speed PI proportional gain
0.1
400.0
4
10
START_SPD_REG_TI
P46 - TiV initial speed PI lead time constant
0.1
3000.
0
80 ms 10
DO_SPD_REACH_THR
P47 - Speed threshold for logic output o.16
0.0
100.0
0
% MOT_SPD_MAX 163.84
RES2_TRACK_LOOP_BW
P48 - Tracking loop bandwidth direct
decoding of resolver2
100 10000 1800
rad/s
1
RES2_TRACK_LOOP_DAMP P49 - Damp factor Traking loop resolver2
0.00
5.00
0.71
100
DO_SPD_MIN_THR
P50 - Minimum speed for relay 0.0
100.0
2.0
%
MOT_SPD_MAX
163.84
PRC_MOT_SPD_MAX
P51 - Maximum speed for alarm 0.0
125.0 120.0
%
MOT_SPD_MAX
163.83
PRC_FLX_MIN
P52 - Minimum Flux admitted 0.0
100.0
2
%
MOT_FLX_NOM
40.96
DRV_I_NOM
P53 - Rated drive current
0.0
3000.
0
0 A 10
PRC_AO1_10V
P57 - % value of 10V for analog output A
100.0 400.0
200
%
10
PRC_AO2_10V
P58 - % value of 10V for analog output B
100.0 400.0
200
%
10
HYST_DO_SPD
P59 - Minimum and maximum speed
reached output hysteresis
0.0 100.0
1.0 %
MOT_SPD_MAX 163.84
RES_PAR_KEY
P60 - Access Key to reserved parameters
0
65535
0
1
PRC_MOT_I_NOM
P61 - Rated motor current ( I NOM MOT)
10.0 100.0
100
% DRV_I_NOM
327.67
MOT_V_NOM
P62 - Rated motor voltage
100.0
1000.
0
380 Volt 10
MOT_F_NOM
P63 - Rated motor frequency
10.0
1000.
0
50.0 Hz 10
PRC_MOT_V_MAX
P64 - Max. operating voltage 1.0
200.0
100
%
MOT_V_NOM
40.96
MOT_SPD_MAX
P65 - Max. operating speed (n MAX)
50
60000 2000
RPM
1
MOT_COS_PHI
P66 - Nominal power factor
0.500 1.000 0.894
1000
MOT_POLE_NUM
P67 - Number of motor poles
1
12
4
1
RES_POLE
P68 - Number of absolute sensor poles
1
12
2
1
ENC_PPR
P69 - Number of encoder pulses/revolution
0
60000 1024
pulses/rev
1
PRC_MOT_I_THERM
P70 - Motor thermal current
10.0 110.0
100 % PRC_MOT_I_NOM
10
MOT_TF_THERM
P71 - Motor thermal time constant
30
2400
180
s
1
PRC_MOT_I_T_NOM
P72 - Nominal torque current 5.0
100.0
95.2
%
PRC_MOT_I_NOM
327.67
PRC_MOT_I_FLX_NOM
P73 - Nominal flux current 5.0
100.0
30.2
%
PRC_MOT_I_NOM
327.67
T_ROTOR
P74 - Rotor time constant Tr
10
10000
182
ms
1
T_STATOR
P75 - Stator time constant Ts
0.0
50.0
8.5
ms
10
PRC_DELTA_VRS
P76 - Voltage drop due to stator resistor
1.0
25.0
2.0
% MOT_V_NOM
327.67
PRC_DELTA_VLS
P77 - Voltage drop due to leakage
inductance
5.0 100.0
20.0 %
MOT_V_NOM 327.67
MOT_T_NOM
P78 - Nominal motor torque
0.5
3000.
0
0.0 Nm 10
TEST_CONN_FEEDBACK
P79 - Connection tests: Encoder: pulses
counted, Resolver or Sin Cos Enc: time
reading
-19999 19999
0
0
V_REG_KP
P80 - Kpi voltage regulator proportional gain
0.1
100.0
9.1
10
V_REG_TF
P82 - Tfi voltage regulator (filter) time
constant
0.0
1000.
0
11 ms 10
I_REG_KP
P83 - Kpc current regulator proportional gain
0.1
100.0
2.6
10
I_REG_TI
P84 - Tic current regulator lead time
constant
0.0
1000.
0
8.5 ms 10
I_REG_TF
P85 - Tfc current regulator (filter) time
constant
0.0 25.0
0
ms
10
DCBUS_REG_KP
P86 - Kp3 Bus control proportional gain
0.05 10.00
3.5
100
MAIN_SUPPLY
P87 - Main Supply voltage
180.0 780.0
400
V rms
10
MAXV_VF
P88 - High precision analog speed
reference value: Voltage matches max.
speed
2500 10000 10000
mVolt
1
RES_TRACK_LOOP_BW
P89 - Tracking loop bandwidth direct
decoding of resolver
100 10000 1800
rad/s
1
RES_TRACK_LOOP_DAMP P90 - D Traking loop bandwidth
0.00
5.00
0.71
100
MOT_TEMP_MAX
P91 - Maximum motor temperature (if read
with PT100)
0.0 150.0
130
°C
10
MODBUS_ADDR
P92 - Serial identification number
0
255
1
1
MODBUS_BAUD
P93 - Serial baud rate
192
Kbit/s
1
MOT_PRB_RES_THR
P95 - Motor NTC or PTC resistance value
for alarm
0 19999 1500
Ohm
1
PRC_MOT_DO_TEMP_THR
P96 - Motor thermal logic output 14 cut-in
threshold
0.0 200.0
100
%
PRC_MOT_I_THERM
40.96
DCBUS_MIN_MAIN_LOST
P97 - Minimum voltage level for forced
mains off
100.0
1200.
0
425 V 10