120
DISPLAY_SEL
C14 - Display selection
0
127
0
1
AO1_SEL
C15 - Meaning of programmable analog
output 1
-99 100 11
1
AO2_SEL
C16 - Meaning of programmable analog
output 2
-99 100 4
1
SENSOR2_SEL
C17 - Sensor2 selection
0
13
0
1
EN_TIME_DEC_ENC2
C18 - Enable incremental encoder2 time
decode
0 1 0
1
EN_SENSOR2_TUNE
C19 - Enable sensor2
auto-tuning 0 1 0 1
EN_INV_POS2_DIR
C20 - Invert sensor2 positive cyclic
versus
0 1 0
1
SW_RUN_CMD
C21 - Run software enable
0
1
1
1
LEM_SEL
C22 - LEM selection
0
1
1
1
EN_SYNC_REG
C23 - Enable CANOpen SYNC traking
loop
0 1 0
1
DC_BUS_FULL_SCALE
C24 - DC Voltage drive full scale
0
2
0
V
1
RES2_DDC_BW
C25 - Second Resolver DDC bandwidth
0
1
0
Hz
1
EN_RND_RAMP
C27 - Rounded ramp
0
1
0
1
EN_STOP_MIN_SPD
C28 - Stop with minimum speed
0
1
0
1
DRV_SW_EN
C29 - Drive software enable
0
1
1
1
ALL_RESET
C30 - Reset alarms
0
1
0
1
EN_MOT_THERMAL_ALL
C32 - Motor thermal switch ' Block drive’
0
1
1
1
MOT_THERM_CURV_SEL C33 - Auto-ventilated thermal motors
0
3
0
1
MAIN_LOST_SEL
C34 - Managing mains failure
0
3
0
1
ALL_RST_ON_MAIN
C35 - Automatic alarm reset when
mains back on
0 1 0
1
EN_PW_SOFT_START
C37 - Enable soft start
0
1
1
1
MAGN_SEL
C38 - Motor Magnetization selection
0
2
0
1
EN_TEST_CONN
C41 - Enable sensor and motor phase
tests
0 1 0
1
EN_AUTOTUNING
C42 - Enable
auto-tunings
0 3 0 1
ALL_COUNT_RESET
C44 - Reset alarm counters
0
2
0
1
RECT_BRIDGE_SEL
C45 - Rectification bridge 0 = diodes, 1
= semicontrolled
0 1 0
1
MOT_THERM_PRB_SEL
C46 - Enable motor thermal probe
management (PT100/PTC/NTC)
0 4 1
1
EN_DCBUS_MAX_CTRL
C47 - Enable smart brake
0
1
0
1
CANOPEN_BAUD_SEL
C48 - CAN Baud rate
0
7
0
1
ENC_OUT_ZERO_TOP
C49 - TOP zero phase for simulated
encoder
0 3 0
1
ENC_OUT_DIR
C50 - Invert channel B simulated
encoder
0 1 0
1
ENC_OUT_PPR_SEL
C51 - Choose pulses ev. simulated
encoder
0 11 5
1
ENC_OUT_SEL
C52 - Simulated encoder selection
0
4
0
1
EN_TEST_SPD
C53 - Enable test of start-up time
0
2
0
1
OPD_ENC_OUT_SEL
C54 – Internal Simulated Encoder
selection
0 2 0
1
I_RELAY_SEL
C55 - Current relay output
0
2
0
1
I_OVR_LOAD_SEL
C56 - Current overload
0
3
3
1
DRV_THERM_PRB_SEL
C57 - Enable radiator heat probe
management (PTC/NTC)
0 1 1
1
DIS_I_DECOUP
C59 - Disable dynamic deco
feedfoward
0 1 0
1
PAR_ACT_BANK
C60 - Parameter bank active
0
1
0
1
DEF_PAR_RD
C61 - Read default parameters
0
1
0
1
EEPROM_PAR_RD
C62 - Read parameters from EEPROM
0
1
0
1
EEPROM_PAR_WR
C63 - Save parameters in EEPROM
0
1
0
1
EN_FLDBUS
C64 - Enable fieldbus manage
0
3
0
1
RES_DDC_BW
C66 - Resolver DDC bandwidth
0
1
0
Hz
1
RES_CARR_FRQ_RATIO
C67 - Resolver carrier frequency
-3
3
0
1
EN_SENSOR_TUNE
C68 - Enable sensor auto-tuning
0
1
0
1
EN_TF2_SPD_REG
C69 - Enable 2nd order filter on speed
regulator
0 1 0
1
EN_SINCOS_PREC_POS
C70 - Enable SinCos Analog-Digital
compensation into position
0 1 0
1
EN_BRAKE_R_PROT
C71 – Enable braking resistance
protection
0 1 0
1
EN_SPD_REG_D
C72 - Enable feedforward
0
1
0
1
EN_STO_ONLY_SIG
C73 - Enable Safety STOP only like
signaling
0 1 0
1
Summary of Contents for MINIOPD EXP
Page 2: ......
Page 51: ...51 User s manual...
Page 56: ...56...
Page 73: ...73 User s manual 3 3 2 PID CONTROLLER...
Page 74: ...74...
Page 123: ......