86
2013
VAR
UNSIGNED16
ingressi
Logical status of the 8
inputs of the terminal board
Reading
2014 VAR UNSIGNED16
ingressi_hw
Logical status of the 3
inputs from the power
Reading
2015
VAR
UNSIGNED16
uscite_hw
Logical status of the 4 digit
outputs
Reading
2016 VAR
UNSIGNED
32
Tab_inp_dig_field
Values set by CAN of the
output logical function
Reading/writing
2017
VAR
UNSIGNED16
stato
Variable of the drive’s status
Reading
2018 VAR UNSIGNED16
allarmi
Drive
alarms’
status
Reading
2019
VAR
UNSIGNED16
abilitazione_allarmi
Word for enabling drive’s
alarms
Reading
201A VAR INTEGER16
f_fieldbus
Speed reference in % of
n
MAX
in 16384
Reading/writing
201B
VAR
INTEGER16
limit_fieldbus
torque limit in % di Tnom in
4095
Reading/writing
201C VAR INTEGER16
trif_fieldbus
torque reference in % di
Tnom in 4095
Reading/writing
201D
VAR
INTEGER16
theta_fieldbus
Speed reference in electr.
pulses x Tpwm
Reading/writing
201E ARRAY INTEGER16
Tab_dati_applicazione
[100]
Data Area available for the
application
Reading/writing
201F
VAR
UNSIGNED32
Ingressi_wr
Writing standard logical
inputs
Reading/writing
2020 VAR UNSIGNED32
Ingressi
Writing application logical
inputs
Reading
2021
VAR
UNSIGNED32
Uscite_standard_rd
Reading standard inputs
Reading
2022 VAR UNSIGNED16
word_vuota
Unused Word
Reading/writing
2023
VAR
UNSIGNED32
double_vuota
Unused Double word
Reading/writing
2024 VAR DOMAIN
Tab_formati_extra
Formats of extra
parameters
Reading
4.2.6.1 FORMAT PARAMETERS TABLE (TAB_FORMAT 2001H)
This table is made by 800word (200*4) 4 words for each parameter :
1
st
word : it defines the parameter typology, its internal representation and the number of decimal and
integer digits which are shown up on the display. Each nibble has the following meaning:
0x 0 0 0 0 (in hexadecimal)
number of digits visualised in decimal
number of digits visualised in integer
internal representation :
0 Direct
value
1 Percent of the base (100/base)
2 Proportional to the base (1/base)
3 Direct value unsigned
Type of parameter:
0 Not managed
1 free (changeable on-line)
2 Reserved (changeable off-line + key P60)
4 TDE (changeable off-line + key P99)
For example:
0x1231
Æ
free parameter proportional to the base: the real value is = internal representation/base
(4
th
word).
2
nd
word : it defines the min. value admitted in the internal representation of the parameter