108
7.4.1 UNDER-MENU OF PARAMETERS, APPLICATION PARAMETERS
AND CONNECTIONS MANAGEMENT (PAR, APP E CON)
From “
PAR
” or “
CON
” You enter into the undermenu list pressing “S”; once
entered into the list is able look through the parameters or the existing
connections by pressing the keys “
+
” or “
–
” to move in increase or in
decrement; even in this case the list is circular. At the number
corresponding to the various parameters or connections appear the letter “
r
”
if they are reserved, “
t
” if reserved in the TDE MACNO and the letter “
n
” if it
modification requires that the converter in not in run (offline); all the
reserved parameters are of type “
n
” modifiable only by stop (offline). If You
pressed the key “
S
” comes visualized the value of the parameter or of the
connection that may be read; at this point repress “
S
” once You return to
the undermenu list, press twice “
S
” in fast succession (less 1 seconds),
return to the main menu. The system returns automatically to the status of
rest and after 10 seconds of have past inactivity. To modify the value of the
parameter or of connection once entered into visualization it necessary
press both keys “
+
” and “
–
”; in that moment it starts to flash the decimal
point of the first figure to the left warning that from that moment the
movement of the keys and “
+
” modifies the value; the change of value may
only by stop if the parameter is of kind “
n
” and only after having set up the
code of access P60, if the parameter is of the kind “
r
”, only after having set
up the code of P99 (access for the reserved parameters TDE MACNO),
kind “
t
”. The parameters and the reserved connections TDE MACNO
doesn’t appear in the list if doesn’t call the code of P99. Once the value is
corrected You press the key “
S
” return to the under menu list making
operational the parameter or the corrected connection; if after correct the
value want go out without change the values wait 10 seconds; if the value is
no touched for the exit press again the “
S
” key (it is operative the same
original value). About parameters and connections, the return to the status
of rest display is in automatically way after 10 seconds from any kind of
visualization.