TCS 3000 Register Start Up:
Before placing this register into service you will receive a warning when you turn on the register
to calibrate the device before using. It will read as follows:
Caution
Before Placing this product into service, make sure that the register
has been properly calibrated and setup for the type of fluid being
measured. This includes calibration factor, compensation type,
compensation parameter, product type, valve settings, no flow
timeout and others. Refer to the operation manual supplied with the
register for instructions. Failure to properly calibrate and setup the
register can result in unexpected operation, inaccurate measure-
ments and damage to equipment or property.
Navigation Keyboard Functions
Start/Enter Key
Stop/Cancel Key
Arrow Keys
Power Light
Power Light
Allows you to see that there is power to the electronic register.
Start/Enter Key
Allows you to enter register functions and start deliveries.
Stop/Cancel Key
Allows you to stop a delivery and cancel an operation.
Arrow Keys
Allow you to move to different fields on the Register.
WARNINGS:
SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS C AND D HAZARDOUS LOCATIONS, OR UNCLASSIFIED
LOCATIONS.
WARNING– EXPLOSION HAZARD– DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UN-
LESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS
WARNING– EXPLOSION HAZARD– SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS
1, DIVISION 2.