15
Select Function
ZERO FLOW TIMEOUT
Feature will complete a delivery transaction if the user does not press the STOP key.
Enter whole numbers in Seconds for the timeout setting and press ENTER.
NOTE: Factory setting is 180 seconds, 3 minutes after the last pulse transmission to the TCS 3000 regis-
ter. This feature CANNOT be disabled. For desired extended periods, utilizer a large number to have the
Timeout ignored.
PAUSE OPTIONS
Pause controls how pump control is used.
Allow Pause
Allow Pause Pauses the pump during the delivery
Pause Pump
Pause Pump stops the delivery completely during delivery.
5) AUXILIARY DEVICES
EXTERNAL DISPLAY
The External Display setting is for the specific manufacturers of large LED displays. This
setting is for serial communication to an ancillary display that will read the same data that is
displayed on the TCS 3000 register.
Enable/Disable
Enable or disable and press ENTER
Configure
Select Type:
Red Lion LD is currently the only external display available today
Address:
Display Address from 1 to 99 and press ENTER
Display Data
Choose the information to display on External Display and press
ENTER
- Delivery Gross
- Delivery Net
- Delivery Volume
- Delivery Total (Currency)
- Flow Rate
- Mass
Test
This is a test sequence of numbers to exhibit on external display
AIR ELIMINATOR
The Air Eliminator is for the electronic actuation of a solenoid exhaust vent and a down
stream valve, when a level sensor switches.
AE Enable/Disable
Enable or disable for operation
AE Detection
Select Normally Open or Closed for level sensor detection
AE Relay
Enable or disable exhaust vent solenoid valve actuation
ADDITIVE INJECTOR
This feature is not currently enabled