26
Select Function
PREVIEW PRICING
Preview Pricing will show the Product price and taxes.
3) ACTIVATE PRODUCT
Activate Product allows you to activate a product for a specific Shift. When liquid in your
tank changes, you can change the product and calibration to match.
- To Activate a product, highlight the product and press ENTER.
4) DEACTIVATE PRODUCT
Deactivate Product allows you to deactivate an active Shift product. When liquid in
your tank changes, you can also change the product.
5) PRODUCT TIMING
Product Timing allows auxiliary device settings to be changed to suite the needs of the
application. Currently set up for Preset Valve, Air Eliminator Hold and Hose Volume.
Product Timing is product specific, adjusting the actuation or closure type.
PRESET TIMING
Preset Timing adjusts the valve closure type for preset or security valves.
Highlight the Preset Timing function desired and press ENTER. This will be chosen as your
default setting for the specific Product.
Full-Auto
Full Automatic tune preset shutoff for Solenoid S1 (fast) and S2 (slow) flow valves.
Semi-Auto
Semi-Automatic tune preset shutoff for Solenoid S2 (slow) flow valve. Highlight Semi Auto
and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER.
Next Fix
Next Fix is an automatic tune shutoff, however it will allow the preset to overrun batch
amount. Designed to automatically correct the shutoff on the next preset delivery. Highlight
Next Fix and press ENTER. Input Solenoid S1 (fast) flow valve closure and press ENTER.
Static
Static settings for the Solenoid S1 (fast) and S2 (slow) flow valves. There is no automatic
correction for zero point shutoff. Highlight Static and press ENTER. Input Solenoid S1
(fast) flow valve closure and Solenoid S2 (slow) flow valve and press ENTER.
AIR ELIMINATOR HOLD
When the TCS 3000 senses air, it will actuate the Solenoid S1 and S2 to shut off and
open the Auxiliary Relay for the exhaust port to remove air from the system. Highlight Air
Eliminator Hold and press Enter. The HOLD (s) is the adjustable setting for the Auxiliary
Relay closure in Seconds. Input value in Seconds and press ENTER.
STARTUP VOLUME
6) PROUCT LISTS
Displays a list of Active, Inactive and Un-Calibrated products on the TCS 3000. To view
these Products, highlight the selection and press ENTER.