3-23
Fig. 3.77
Fig. 3.76
Fig. 3.75
■
REASSEMBLING TORQUE
CONVERTER HOUSING
①
With a gasket, install the charging pump (1)
on the torque converter housing.
②
Install the strainer (1) on the converter
housing. With an “O”-ring (2) and gasket (3),
install the cover (4).
③
Install the converter relief valve (1) and
regulator valve (2) on the converter housing.
With a gasket (3), install the cover (4).