TANDBERG 2000 MXP
216
The TANDBERG codec contains a DVI-I plug that can transmit either digital DVI signals or
standard analog VGA signals, depending on what type of monitor is connected.
DVI Specifications
TANDBERG DVI-I follows the VESA Monitor Timing Standard v1.08, also knows as Display
Monitor Timing (DMT).
Supported DVI cables:
TANDBERG supports DVI-D Single-Link, DVI-A and DVI-I Single-Link format cables.
DVI-D cables transmit digital T.M.D.S. signals, DVI-A cables transmit analog VGA signals and
DVI-I cables can transmit either digital or analog signals.
It is possible to extend existing DVI cables by the use of extension cables. The maximum cable
length however, is 5 meters. Going beyond that may result in quality loss.
Pin
Signal
Assignment
Pin
Signal Assignment
Pin
Signal Assignment
1
T.M.D.S. Data2-
9
T.M.D.S. Data1-
17
T.M.D.S. Data0-
2
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18
T.M.D.S. Data0+
3
T.M.D.S. Data2/4
Shield
11
T.M.D.S. Data1/3 Shield
19
T.M.D.S. Data0/5
Shield
4
T.M.D.S. Data4-
12
T.M.D.S. Data3-
20
T.M.D.S. Data5-
5
T.M.D.S. Data4+
13
T.M.D.S. Data3+
21
T.M.D.S. Data5+
6
DDC Clock
14
+5V Power
22
T.M.D.S. Clock
Shield
7
DDC Data
15
Ground (return for +5V,
HSync and VSync)
23
T.M.D.S. Clock+
8
Analog Vertical
Sync
16
Hot Plug Detect
24
T.M.D.S. Clock-
C1
Analog Red
C2
Analog Green
C3
Analog Blue
C4
Analog Horizontal
Sync
C5
Analog Ground
(analog, R, G & B return)
DVI-I - Combined Analog and Digital Connector Pin Assignments.