Tandberg Data
Receive Diagnostic Results
21-2
Tandberg SLR Product Line SCSI Functional Specifications
Page Code
The following Page Codes are available:
00h: The analysis data returned will be from the last
SEND
DIAGNOSTICS command.
98h: The analysis data returned will be from the last completed Stand
Alone Diagnostics test. The results from the Stand Alone Diagnostic survives
Reset/Power On.
Note that this Page Code is only valid when the PCV bit is set to one.
Allocation Length
This field specifies the length in bytes allocated by
the initiator for receipt of the analysis data. For each
page returned, the allocation length is the page length
plus 4 bytes. The number of data bytes returned by the
drive might be less then allocation length, depending on
the number of diagnostic tests that has failed. The
Drive terminates the DATA-IN phase when Allocation
Length bytes have been transferred or when all available
analysis data have been transferred, whichever is less.
An Allocation Length of zero indicates no analysis data
will be transferred.