![Tandberg Data SLR7-140 PROGRAMMER Manual Download Page 284](http://html1.mh-extra.com/html/tandberg-data/slr7-140-programmer/slr7-140-programmer_manual_3496838284.webp)
Tandberg Data
Read Block Limits
18-2
Tandberg SLR Product Line SCSI Functional Specifications
18.4. Exception Handling
See sections on Error Conditions For All Commands and
Deferred Errors.
18.5. Phase Sequencing
In this section the possible SCSI-bus phase sequences
during execution of the command are described. Section
3.2.1 has more details about the generic phases in the
brackets.
<sequence 1>
:=
<initiator-part> <message-out> <command> <disconnect> <reconnect>
<data-in> <completed>
The Drive will disconnect when the CDB has been
transferred. The Drive will reconnect and then transfer
the parameter list.
<sequence 2>
:=
<initiator-part> <message-out> <command> <completed>
This sequence will be used when the command is executed
and the Initiator does not allow disconnection.